Charalampos Schizas1, Dimitris Karalekas.
Abstract
In this work, the mechanical behaviour of a photocured Ormocomp(®) hybrid material is investigated. Its biocompatible nature has attracted a growing interest for microfabrication applications in biomedicine and tissue engineering. Measurements of in situ solidification strain development and achieved degree of curing, as obtained using a fibre optic sensor, are presented. The results show that the solidification strains generated during UV-curing are significant at the maximum achieved degree of curing. The mechanical response (Young's modulus) of the material was investigated by testing of thin-film and regular size specimens. It was found that the measured mean elastic modulus of the thin-film specimens was of the same order of magnitude as that of the larger specimens but noticeably smaller.Mesh:
Substances:
Year: 2010 PMID: 21094483 DOI: 10.1016/j.jmbbm.2010.09.010