Literature DB >> 21094376

Alignment of high resolution magic angle spinning magnetic resonance spectra using warping methods.

Guro F Giskeødegård1, Tom G Bloemberg, Geert Postma, Beathe Sitter, May-Britt Tessem, Ingrid S Gribbestad, Tone F Bathen, Lutgarde M C Buydens.   

Abstract

The peaks of magnetic resonance (MR) spectra can be shifted due to variations in physiological and experimental conditions, and correcting for misaligned peaks is an important part of data processing prior to multivariate analysis. In this paper, five warping algorithms (icoshift, COW, fastpa, VPdtw and PTW) are compared for their feasibility in aligning spectral peaks in three sets of high resolution magic angle spinning (HR-MAS) MR spectra with different degrees of misalignments, and their merits are discussed. In addition, extraction of information that might be present in the shifts is examined, both for simulated data and the real MR spectra. The generic evaluation methodology employs a number of frequently used quality criteria for evaluation of the alignments, together with PLS-DA to assess the influence of alignment on the classification outcome. Peak alignment greatly improved the internal similarity of the data sets. Especially icoshift and COW seem suitable for aligning HR-MAS MR spectra, possibly because they perform alignment segment-wise. The choice of reference spectrum can influence the alignment result, and it is advisable to test several references. Information from the peak shifts was extracted, and in one case cancer samples were successfully discriminated from normal tissue based on shift information only. Based on these findings, general recommendations for alignment of HR-MAS MRS data are presented. Where possible, observations are generalized to other data types (e.g. chromatographic data).
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21094376     DOI: 10.1016/j.aca.2010.09.026

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  Variable reference alignment: an improved peak alignment protocol for NMR spectral data with large intersample variation.

Authors:  Neil MacKinnon; Wencheng Ge; Amjad P Khan; Bagganahalli S Somashekar; Pratima Tripathi; Javed Siddiqui; John T Wei; Arul M Chinnaiyan; Thekkelnaycke M Rajendiran; Ayyalusamy Ramamoorthy
Journal:  Anal Chem       Date:  2012-05-29       Impact factor: 6.986

Review 2.  Recommended strategies for spectral processing and post-processing of 1D 1H-NMR data of biofluids with a particular focus on urine.

Authors:  Abdul-Hamid Emwas; Edoardo Saccenti; Xin Gao; Ryan T McKay; Vitor A P Martins Dos Santos; Raja Roy; David S Wishart
Journal:  Metabolomics       Date:  2018-02-12       Impact factor: 4.290

3.  First Trimester Urine and Serum Metabolomics for Prediction of Preeclampsia and Gestational Hypertension: A Prospective Screening Study.

Authors:  Marie Austdal; Line H Tangerås; Ragnhild B Skråstad; Kjell Salvesen; Rigmor Austgulen; Ann-Charlotte Iversen; Tone F Bathen
Journal:  Int J Mol Sci       Date:  2015-09-08       Impact factor: 5.923

4.  Getting your peaks in line: a review of alignment methods for NMR spectral data.

Authors:  Trung Nghia Vu; Kris Laukens
Journal:  Metabolites       Date:  2013-04-15

Review 5.  Analytical methods in untargeted metabolomics: state of the art in 2015.

Authors:  Arnald Alonso; Sara Marsal; Antonio Julià
Journal:  Front Bioeng Biotechnol       Date:  2015-03-05

6.  Feasibility of MR metabolomics for immediate analysis of resection margins during breast cancer surgery.

Authors:  Tone F Bathen; Brigitte Geurts; Beathe Sitter; Hans E Fjøsne; Steinar Lundgren; Lutgarde M Buydens; Ingrid S Gribbestad; Geert Postma; Guro F Giskeødegård
Journal:  PLoS One       Date:  2013-04-17       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.