Literature DB >> 21093247

Enlarged gold-tipped silicon microprobe arrays and signal compensation for multi-site electroretinogram recordings in the isolated carp retina.

Tetsuhiro Harimoto1, Kuniharu Takei, Takeshi Kawano, Akito Ishihara, Takahiro Kawashima, Hidekazu Kaneko, Makoto Ishida, Shiro Usui.   

Abstract

In order to record multi-site electroretinogram (ERG) responses in isolated carp retinae, we utilized three-dimensional (3D), extracellular, 3.5-μm-diameter silicon (Si) probe arrays fabricated by the selective vapor-liquid-solid (VLS) growth method. Neural recordings with the Si microprobe exhibit low signal-to-noise (S/N) ratios of recorded responses due to the high-electrical-impedance characteristics of the small recording area at the probe tip. To increase the S/N ratio, we designed and fabricated enlarged gold (Au) tipped Si microprobes (10-μm-diameter Au tip and 3.5-μm-diameter probe body). In addition, we demonstrated that the signal attenuation and phase delay of ERG responses recorded via the Si probe can be compensated by the inverse filtering method. We conclude that the reduction of probe impedance and the compensation of recorded signals are useful approaches to obtain distortion-free recording of neural signals with high-impedance microelectrodes. Copyright Â
© 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21093247     DOI: 10.1016/j.bios.2010.10.014

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Three-micrometer-diameter needle electrode with an amplifier for extracellular in vivo recordings.

Authors:  Yuto Kita; Shuhei Tsuruhara; Hiroshi Kubo; Koji Yamashita; Yu Seikoba; Shinnosuke Idogawa; Hirohito Sawahata; Shota Yamagiwa; Xian Long Angela Leong; Rika Numano; Kowa Koida; Takeshi Kawano
Journal:  Proc Natl Acad Sci U S A       Date:  2021-04-20       Impact factor: 11.205

2.  In vivo neuronal action potential recordings via three-dimensional microscale needle-electrode arrays.

Authors:  Akifumi Fujishiro; Hidekazu Kaneko; Takahiro Kawashima; Makoto Ishida; Takeshi Kawano
Journal:  Sci Rep       Date:  2014-05-02       Impact factor: 4.379

3.  Single 5 μm diameter needle electrode block modules for unit recordings in vivo.

Authors:  H Sawahata; S Yamagiwa; A Moriya; T Dong; H Oi; Y Ando; R Numano; M Ishida; K Koida; T Kawano
Journal:  Sci Rep       Date:  2016-10-25       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.