The impact of prolonged rotary ventricular assist device support upon ventricular geometry and flow kinetics.

Robert M Weiss1, Richard E Kerber, Jennifer L Goerbig-Campbell, Melissa K Davis, Barry M Cabuay, Guha Ashrith, Wassef Karrowni, James E Davis, Frances L Johnson.   

Abstract

BACKGROUND: The aim of this study was to determine the impact of prolonged left ventricular assist device (VAD) support on cardiac ventricular geometry and VAD flow kinetics.
METHODS: Nineteen patients with end-stage heart failure underwent the implantation of HeartMate II rotary flow VADs. Left and right ventricular geometry and VAD flow kinetics were assessed by transthoracic echocardiography early (7 ± 1 days) and late (113 ± 21 days) after VAD implantation.
RESULTS: Left ventricular end-diastolic internal dimension decreased by 21% and 35%, respectively, early and late after VAD implantation (n = 19; P < .001 vs before VAD implantation). Right ventricular end-diastolic internal dimension did not decrease at either time. Hemodynamic trends were similar. VAD inflow obstruction by myocardium was observed in eight patients, seven of whom demonstrated significantly increased variation of VAD inflow during the cardiac cycle ("pulsatility") detected by Doppler studies. Medical or surgical intervention returned VAD flow patterns toward baseline in seven of eight patients with VAD obstructions.
CONCLUSIONS: Prolonged rotary VAD support unloads the left ventricle, with modest effects on the right ventricle. These changes are often associated with alterations of VAD flow kinetics, requiring therapeutic intervention. These findings indicate the usefulness of echocardiographic surveillance in patients undergoing prolonged VAD support.
Copyright © 2010 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21093217     DOI: 10.1016/j.echo.2010.10.009

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

Review 1.  Left ventricular assist device unloading effects on myocardial structure and function: current status of the field and call for action.

Authors:  Stavros G Drakos; Abdallah G Kfoury; Craig H Selzman; Divya Ratan Verma; John N Nanas; Dean Y Li; Josef Stehlik
Journal:  Curr Opin Cardiol       Date:  2011-05       Impact factor: 2.161

2.  Effects of the HeartMate II left ventricular assist device as observed by serial echocardiography.

Authors:  Carrie B Chapman; Salman Allana; Nancy K Sweitzer; Takushi Kohmoto; Margaret Murray; David Murray; Maryl Johnson; Peter S Rahko
Journal:  Echocardiography       Date:  2013-01-11       Impact factor: 1.724

3.  Comparison of left ventricular geometry after HeartMate II and HeartWare left ventricular assist device implantation.

Authors:  Morteza Tavakkoli Hosseini; Aron Frederik Popov; Andre Ruediger Simon; Mohamed Amrani; Toufan Bahrami
Journal:  J Cardiothorac Surg       Date:  2013-02-28       Impact factor: 1.637

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.