Clinical outcomes of midclavicular fractures treated with titanium elastic nails.

Yun-feng Chen1, Bing-fang Zeng, Yu-jie Chen, Hai-ming Wang, Jian-feng Xue, Yi-min Chai, Xue-tao Xie, Chi Zhang.   

Abstract

BACKGROUND: Midclavicular fractures are common clinically, accounting for about 76% of all clavicular fractures. Recent studies have revealed a previously unrecognized incidence of nonunion and malunion after conservative treatment of more severe midclavicular fractures. Our aim was to evaluate the clinical outcomes of midclavicular fractures treated with titanium elastic nails.
METHODS: From February 2005 to February 2007, 41 patients with displaced midclavicular fractures received open reduction and internal fixation with a titanium elastic nail inserted through the sternal end of the clavicle. We evaluated the visual analogue scale (VAS), the Constant score and the Disabilities of the Arm, Shoulder and Hand (DASH) scale to determine outcomes.
RESULTS: A mean follow-up of 14.5 months (range 7-24 mo) revealed radiographic fracture union in all patients with an average clinical healing time of 2.2 months. Mean subjective pain 3 days after surgery was significantly lower than the day before surgery (p < 0.001). The mean range of motion 3 days after surgery was significantly improved compared with the day before surgery (p < 0.001). The nails were removed in all patients a mean of 7.2 months (range 5.4-9.5 mo) after surgery, and no fractures recurred. The mean postoperative DASH score was 2.5 (range 0.5-8.0) and the mean postoperative Constant score was 95.2 (range 86.5-97.0).
CONCLUSION: Limited open reduction and internal fixation with titanium elastic nails is a safe and minimally invasive surgical procedure for the treatment of displaced midclavicular fractures in adults and achieves good functional results and high patient satisfaction.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21092430      PMCID: PMC2993033     

Source DB:  PubMed          Journal:  Can J Surg        ISSN: 0008-428X            Impact factor:   2.089


  17 in total

1.  Closed treatment of displaced middle-third fractures of the clavicle gives poor results.

Authors:  J M Hill; M H McGuire; L A Crosby
Journal:  J Bone Joint Surg Br       Date:  1997-07

2.  Treatment of clavicular aseptic nonunion: comparison of plating and intramedullary nailing techniques.

Authors:  C C Wu; C H Shih; W J Chen; C L Tai
Journal:  J Trauma       Date:  1998-09

3.  A clinical method of functional assessment of the shoulder.

Authors:  C R Constant; A H Murley
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

4.  Plate fixation of middle-third fractures of the clavicle in the semi-professional athlete.

Authors:  Olivier Verborgt; Kathleen Pittoors; Francis Van Glabbeek; Geert Declercq; Rudy Nuyts; Johan Somville
Journal:  Acta Orthop Belg       Date:  2005-02       Impact factor: 0.500

5.  Plating of fresh clavicular fractures: results of 122 operations.

Authors:  J Poigenfürst; G Rappold; W Fischer
Journal:  Injury       Date:  1992       Impact factor: 2.586

6.  Measuring the whole or the parts? Validity, reliability, and responsiveness of the Disabilities of the Arm, Shoulder and Hand outcome measure in different regions of the upper extremity.

Authors:  D E Beaton; J N Katz; A H Fossel; J G Wright; V Tarasuk; C Bombardier
Journal:  J Hand Ther       Date:  2001 Apr-Jun       Impact factor: 1.950

7.  Complications of plate fixation in fresh displaced midclavicular fractures.

Authors:  O Böstman; M Manninen; H Pihlajamäki
Journal:  J Trauma       Date:  1997-11

8.  Elastic stable intramedullary nailing of midclavicular fractures in athletes.

Authors:  A Jubel; J Andemahr; H Bergmann; A Prokop; K E Rehm
Journal:  Br J Sports Med       Date:  2003-12       Impact factor: 13.800

9.  Fractures of the clavicle in the adult. Epidemiology and classification.

Authors:  C M Robinson
Journal:  J Bone Joint Surg Br       Date:  1998-05

10.  Intramedullary nailing of clavicular midshaft fractures with the titanium elastic nail: problems and complications.

Authors:  Arno Frigg; Paavo Rillmann; Thomas Perren; Martin Gerber; Christian Ryf
Journal:  Am J Sports Med       Date:  2008-12-31       Impact factor: 6.202

View more
  9 in total

Review 1.  Systematic review of complications after intramedullary fixation for displaced midshaft clavicle fractures.

Authors:  Frans-Jasper G Wijdicks; R M Houwert; Peter J Millett; Egbert J J M Verleisdonk; Olivier A J Van der Meijden
Journal:  Can J Surg       Date:  2013-02       Impact factor: 2.089

2.  Closed vs open nailing for displaced middle third fracture of clavicle. Does it matter?

Authors:  Hrushikesh Saraf; Sarang Kasture
Journal:  J Clin Orthop Trauma       Date:  2016-10-13

3.  A retrospective study of titanium elastic stable intramedullary nailing in displaced mid-shaft clavicle fractures.

Authors:  Rajesh Govindasamy; Saravanan Kasirajan; Jimmy Joseph Meleppuram; Fawas Thonikadavath
Journal:  Rev Bras Ortop       Date:  2016-12-30

4.  Midshaft Clavicular Fracture and Titanium Elastic Intra-medullary Nail.

Authors:  Pankaj Kumar Mishra; Anuj Gupta; Suresh Chandra Gaur
Journal:  J Clin Diagn Res       Date:  2014-01-12

5.  Predicting suitability of intramedullary fixation for displaced midshaft clavicle fractures.

Authors:  M H J Hulsmans; M van Heijl; H Frima; O A J van der Meijden; H R van den Berg; A H van der Veen; A C Gunning; R M Houwert; E J M M Verleisdonk
Journal:  Eur J Trauma Emerg Surg       Date:  2017-10-09       Impact factor: 3.693

6.  Validity and responsiveness of the Nottingham clavicle score in clavicle shaft fractures treated with titanium elastic nailing.

Authors:  Karthik Vishwanathan; Shantanu Jain; Amit Patel
Journal:  J Clin Orthop Trauma       Date:  2018-06-19

7.  Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study.

Authors:  Langqing Zeng; Haifeng Wei; Yanjie Liu; Wen Zhang; Yao Pan; Wei Zhang; Changqing Zhang; Bingfang Zeng; Yunfeng Chen
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

8.  Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison.

Authors:  Frans-Jasper Wijdicks; Marijn Houwert; Marcel Dijkgraaf; Diederik de Lange; Koen Oosterhuis; Geertjan Clevers; Egbert-Jan Verleisdonk
Journal:  Int Orthop       Date:  2012-07-31       Impact factor: 3.075

9.  Intramedullary fixation of diaphyseal clavicle fractures using the rockwood clavicle pin: review of 86 cases.

Authors:  William J Marlow; Peter Ralte; Syam Pk Morapudi; Rashpal Bassi; Jochen Fischer; Mohammad Waseem
Journal:  Open Orthop J       Date:  2012-11-16
  9 in total