Literature DB >> 21092034

A newly developed miniaturized heart-lung machine--expression of inflammation in a small animal model.

Heike Schnoering1, Jutta Arens, Estella Terrada, Joerg S Sachweh, Maximilian Runge, Thomas Schmitz-Rode, Ulrich Steinseifer, Jaime F Vazquez-Jimenez.   

Abstract

Cardiopulmonary bypass may cause severe inflammatory reactions and multiorgan failure, especially in premature and low-weight infants. This is due in part to the large area of contact with extrinsic surfaces and the essential addition of foreign blood. Thus, we developed a new miniaturized heart-lung machine (MiniHLM) with a total static priming volume of 102mL (including arterial and venous lines) and tested it in a small animal model. Seven Chinchilla Bastard rabbits were perfused with the MiniHLM (dynamic priming volume 127mL). Seven animals serving as a control were perfused using Dideco Kids and a Stöckert roller pump (modified dynamic priming volume 149mL). The rabbits were anesthetized and sternotomized, followed by cannulation of the aorta and the right atrium. The aorta was clamped for 1h. Blood for examination of inflammation (TNF-α, IL-1β, IL-6, IL-8, and IL-10) and blood gas analysis were taken before skin incision, 5min before opening of the aorta, 15min after opening of the aorta, and 4 h after the initiation of cardiopulmonary bypass. The parameters of inflammation were expressed by means of the comparative C(T) method (ΔΔC(T) method). After gradual reduction of perfusion with the HLM, the heart was decannulated, and the sternum was closed. All rabbits were successfully weaned from cardiopulmonary bypass. Blood gas analysis was unremarkable in all cases. Foreign blood was not administered. Although statistical significance was not achieved, there was a reduced expression of inflammatory markers in the MiniHLM group. The newly developed MiniHLM prototype was tested successfully in a small animal model in terms of technical function and expression of inflammation. Upcoming tests with the industrially manufactured MiniHLM may reveal the advantages of the MiniHLM in comparison with the conventional HLM.
© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21092034     DOI: 10.1111/j.1525-1594.2010.01146.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Cardiopulmonary Bypass in a Mouse Model: A Novel Approach.

Authors:  Nodir Madrahimov; Ruslan Natanov; Erin C Boyle; Tobias Goecke; Ann-Kathrin Knöfel; Valentyna Irkha; Anna Solovieva; Klaus Höffler; Ulrich Maus; Christian Kühn; Issam Ismail; Gregor Warnecke; Malakh-Lal Shrestha; Serghei Cebotari; Axel Haverich
Journal:  J Vis Exp       Date:  2017-09-22       Impact factor: 1.355

2.  Initial experiences with a centrifugal-pump based minimal invasive extracorporeal circulation system in pediatric congenital cardiac surgery.

Authors:  Alexander Kadner; Paul Philipp Heinisch; Maris Bartkevics; Serena Wyss; Hans-Joerg Jenni; Gabor Erdoes; Balthasar Eberle; Thierry Carrel
Journal:  J Thorac Dis       Date:  2019-06       Impact factor: 2.895

Review 3.  Managing the inflammatory response after cardiopulmonary bypass: review of the studies in animal models.

Authors:  Gabriel Romero Liguori; Alexandre Fligelman Kanas; Luiz Felipe Pinho Moreira
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Jan-Mar
  3 in total