Literature DB >> 21091996

Clinical results of observation of the upper gastrointestinal tract by transgastrostomic endoscopy using an ultrathin endoscope.

Hiroyuki Imaeda1, Naoki Hosoe, Hiromasa Nakamizo, Kazuhiro Kashiwagi, Hidekazu Suzuki, Yoshimasa Saito, Kazuhiro Suganuma, Yosuke Ida, Juntaro Matsuzaki, Eisuke Iwasaki, Yasushi Iwao, Haruhiko Ogata, Toshifumi Hibi.   

Abstract

BACKGROUND AND AIM: Esophagogastroduodenoscopy through the oral cavity of patients who have undergone percutaneous endoscopic gastrostomy (PEG) causes some distress and puts these patients at risk of aspiration pneumonia. The aim of this study was to evaluate results for the upper gastrointestinal tract by transgastrostomic endoscopy using an ultrathin endoscope.
METHODS: The study subjects were 43 patients, who underwent exchange of a PEG button or tube, 20-French or more in diameter. After PEG buttons or tubes were extracted from the gastrostomy tract, an ultrathin endoscope was inserted through the gastrostomy tract. The stomach and the duodenal bulb were observed and the esophagus was observed in retrograde passage. A new PEG button or tube was then inserted. The rate of successful insertion into the esophagus and duodenal bulb, the observation of the gastrostomy site in retroversion in the stomach, and the endoscopic findings were analyzed.
RESULTS: Ninety-nine examinations were carried out. The esophagus could be observed in 95 (96.0%), the duodenum in 92 (92.9%) and the gastrostomy site in the stomach in all. Gastric polyps were detected in four patients, gastric erosions in two, reflux esophagitis in two, polypoid lesion at the gastrostomy tract in two, gastric ulcer scar in one, duodenal ulcer scar in one, early gastric cancer in one and recurrent esophageal cancer in one. Neither discomfort nor complications occurred during transgastrostomic endoscopy.
CONCLUSIONS: Observation of the upper gastrointestinal tract by transgastrostomic endoscopy using an ultrathin endoscope during a gastrostomy button or tube replacement may be useful and safe.
© 2010 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 21091996     DOI: 10.1111/j.1440-1746.2010.06399.x

Source DB:  PubMed          Journal:  J Gastroenterol Hepatol        ISSN: 0815-9319            Impact factor:   4.029


  1 in total

1.  Successful biliary drainage using a metal stent through the gastric stoma.

Authors:  Kazuyuki Matsumoto; Hironari Kato; Koichiro Tsutsumi; Yutaka Akimoto; Daisuke Uchida; Takeshi Tomoda; Naoki Yamamoto; Yasuhiro Noma; Shigeru Horiguchi; Hiroyuki Okada; Kazuhide Yamamoto
Journal:  World J Gastroenterol       Date:  2015-06-28       Impact factor: 5.742

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.