Reproducibility of non-standardised autonomic function testing in the pre-operative assessment screening clinic*.

S W M Keet1, C S E Bulte, C Boer, R A Bouwman.   

Abstract

By convention, autonomic function tests are undertaken under standard test conditions that limit their implementation during routine pre-operative assessment. We therefore evaluated the comparability of autonomic function tests under both non-standardised and standardised test conditions in 20 healthy male subjects. Autonomic function was assessed using an ECG monitor and a continuous non-invasive blood pressure measurement device. Under non-standardised conditions, intraclass correlation for heart rate variability analysis was good for the low and high frequency bands (0.87; 95% CI 0.58-0.96 and 0.83; 95% CI 0.56-0.94, respectively), but moderate (0.65; 95% CI 0.14-0.86) for the very low frequency band; reproducibility was high for the expiration/inspiration ratio (0.89; 95% CI 0.71-0.96), Valsalva ratio (0.76; 95% CI 0.37-0.91) and handgrip test (0.76; 95% CI 0.35-0.91) (all p<0.05) but was low for the response to quick standing. Reproducibility under standardised conditions was comparable to the above values. We demonstrated that reproducibility for most autonomic tests under non-standardised conditions is acceptable and suggest that implementation of these tests during pre-operative assessment may be feasible.
© 2010 The Authors. Anaesthesia © 2010 The Association of Anaesthetists of Great Britain and Ireland.

Mesh:

Year:  2010        PMID: 21091663     DOI: 10.1111/j.1365-2044.2010.06566.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Low pre-operative heart rate variability and complexity are associated with hypotension after anesthesia induction in major abdominal surgery.

Authors:  James R Padley; Erez Ben-Menachem
Journal:  J Clin Monit Comput       Date:  2017-03-14       Impact factor: 2.502

2.  Determinants of vascular and cardiac baroreflex sensitivity values in a random population sample.

Authors:  Anke J Borgers; Bert-Jan H van den Born; Anneke Alkemade; Daan W Eeftinck Schattenkerk; Johannes J van Lieshout; Karel H Wesseling; Peter H Bisschop; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2013-10-19       Impact factor: 2.602

3.  The prevalence of cardiovascular autonomic neuropathy and its influence on post induction hemodynamic variables in patients with and without diabetes; A prospective cohort study.

Authors:  Jorinde A W Polderman; Nicolaas H Sperna Weiland; Michel H Klaver; Judy Biginski; Marijn Horninge; Markus W Hollmann; J Hans DeVries; Rogier V Immink; Benedikt Preckel; Jeroen Hermanides
Journal:  PLoS One       Date:  2018-11-26       Impact factor: 3.240

4.  Modified Valsalva test differentiates primary from secondary cough headache.

Authors:  Russell J M Lane; Paul T G Davies
Journal:  J Headache Pain       Date:  2013-03-28       Impact factor: 7.277