Literature DB >> 21090633

Electrochemical detection of peroxynitrite using a biosensor based on a conducting polymer-manganese ion complex.

Wei Choon Alvin Koh1, Jung Ik Son, Eun Sang Choe, Yoon-Bo Shim.   

Abstract

A peroxynitrite (ONOO(-)) biosensor has been developed through the preparation of a new manganese-[poly-2,5-di-(2-thienyl)-1H-pyrrole)-1-(p-benzoic acid)] (Mn-pDPB) complex. DPB monomer was first synthesized and polymerized for the purpose of providing a polymer backbone for complex formation with Mn(2+) ion. The Mn-pDPB complex was characterized via Magnetomotive Force (MMF) simulation, X-ray photoelectron spectroscopy (XPS), and cyclic voltammetry. The complex selectively enhanced the reduction process of ONOO(-) which was used as the analytical signal for chronoamperometric detection. A polyethyleneimmine (PEI) layer was coated on the complex surface to increase selectivity and stability. The chronoamperometric calibration plot showed the hydrodynamic range of 2.0 × 10(-8)-5.0 × 10(-7) M. The detection limit was determined to be 1.9 (±0.2) × 10(-9) M based on S/N = 3. The microbiosensor, fabricated on a 100 μm diameter Pt tip, was applied in a real rat plasma sample for the detection of spiked concentrations of ONOO(-). The reliability and long-term stability of the microbiosensor was also examined with YPEN-1 cells in vitro, and the results shown were promising.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21090633     DOI: 10.1021/ac102041u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Electrochemical detection of peroxynitrite using hemin-PEDOT functionalized boron-doped diamond microelectrode.

Authors:  Serban F Peteu; Brandon W Whitman; James J Galligan; Greg M Swain
Journal:  Analyst       Date:  2016-03-07       Impact factor: 4.616

2.  GNP-CeO2- polyaniline hybrid hydrogel for electrochemical detection of peroxynitrite anion and its integration in a microfluidic platform.

Authors:  Vijayesh Kumar; Ishita Matai; Ankit Kumar; Abhay Sachdev
Journal:  Mikrochim Acta       Date:  2021-11-27       Impact factor: 5.833

3.  Peroxynitrite Sensor Based on a Screen Printed Carbon Electrode Modified with a Poly(2,6-dihydroxynaphthalene) Film.

Authors:  Ioana Silvia Hosu; Diana Constantinescu-Aruxandei; Maria-Luiza Jecu; Florin Oancea; Mihaela Badea Doni
Journal:  Sensors (Basel)       Date:  2016-11-23       Impact factor: 3.576

4.  Electrochemical Behavior and Voltammetric Determination of a Manganese(II) Complex at a Carbon Paste Electrode.

Authors:  Sophia Karastogianni; Stella Girousi
Journal:  Anal Chem Insights       Date:  2016-01-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.