Literature DB >> 21089193

Dorsally displaced fractures of the distal radius - a study of preferred treatment options among UK trauma and orthopaedic surgeons.

P Hull1, N Baraza, H Whalley, M Brewster, M Costa.   

Abstract

Distal radius fractures are common, and surgeons have in their armament a variety of ways of treating them. In this study, 50 orthopaedic surgeons in the UK were shown five clinical scenarios and radiographs from patients with various fracture patterns of the distal radius, and were asked for their preferred management. There was a wide variation in the preferred treatment for each scenario presented. Across all of the cases, 52% of surgeons preferred to use a volar locking-plate compared with 21% who chose fixation with Kirschner wires. There was very little consensus among surgeons with regard to the optimal method of fixation for patients sustaining dorsally displaced fractures of the distal radius. This disagreement is not surprising as there is currently no high level evidence to guide surgeons as to the best management option for this common and potentially debilitating injury.

Entities:  

Mesh:

Year:  2010        PMID: 21089193     DOI: 10.1142/S0218810410004801

Source DB:  PubMed          Journal:  Hand Surg        ISSN: 0218-8104


  5 in total

1.  Radiological dorsal tilt analysis of AO type A, B, and C fractures of the distal radius treated conservatively or with extra-focal K-wire plus external fixateur.

Authors:  Michael Hoffmann; Malte Schroeder; Kai Kossow; Michaela Gruber-Rathmann; Andreas H Ruecker
Journal:  Skeletal Radiol       Date:  2012-02-05       Impact factor: 2.199

2.  [Volar locking plating for distal radial fractures. Is osteoporosis associated with poorer functional results and higher complications rates?].

Authors:  C Voigt; A Plesz; G Jensen; C Katthagen; H Lill
Journal:  Chirurg       Date:  2012-05       Impact factor: 0.955

Review 3.  Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.

Authors:  Harman Chaudhry; Ydo V Kleinlugtenbelt; Raman Mundi; Bill Ristevski; J C Goslings; Mohit Bhandari
Journal:  Clin Orthop Relat Res       Date:  2015-05-16       Impact factor: 4.176

4.  Type C distal radial fractures treated with conventional AO plates: an easy and cost-saving solution in a locking plate era.

Authors:  Bas Twigt; Michael Bemelman; Koen Lansink; Loek Leenen
Journal:  Int Orthop       Date:  2013-01-11       Impact factor: 3.075

Review 5.  Internal Versus External Fixation for the Treatment of Distal Radial Fractures: A Systematic Review of Overlapping Meta-Analyses.

Authors:  Qingyu Zhang; Fanxiao Liu; Zhenyun Xiao; Zhenfeng Li; Bomin Wang; Jinlei Dong; Yong Han; Dongsheng Zhou; Jianmin Li
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.