Literature DB >> 21086206

FSI simulation of asymmetric mitral valve dynamics during diastolic filling.

S K Dahl1, J Vierendeels, J Degroote, S Annerel, L R Hellevik, B Skallerud.   

Abstract

In this article, we present a fluid-structure interaction algorithm accounting for the mutual interaction between two rigid bodies. The algorithm was used to perform a numerical simulation of mitral valve (MV) dynamics during diastolic filling. In numerical simulations of intraventricular flow and MV motion, the asymmetry of the leaflets is often neglected. In this study the MV was rendered as two rigid, asymmetric leaflets. The 2D simulations incorporated the dynamic interaction of blood flow and leaflet motion and an imposed subject-specific, transient left ventricular wall movement obtained from ultrasound recordings. By including the full Jacobian matrix in the algorithm, the speed of the simulation was enhanced by more than 20% compared to using a diagonal Jacobian matrix. Furthermore, our results indicate that important features of the flow field may not be predicted by the use of symmetric leaflets or in the absence of an adequate model for the left atrium.

Entities:  

Mesh:

Year:  2011        PMID: 21086206     DOI: 10.1080/10255842.2010.517200

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  14 in total

Review 1.  Computational modeling of cardiac valve function and intervention.

Authors:  Wei Sun; Caitlin Martin; Thuy Pham
Journal:  Annu Rev Biomed Eng       Date:  2014-04-16       Impact factor: 9.590

2.  Fluid-structure interaction and structural analyses using a comprehensive mitral valve model with 3D chordal structure.

Authors:  Milan Toma; Daniel R Einstein; Charles H Bloodworth; Richard P Cochran; Ajit P Yoganathan; Karyn S Kunzelman
Journal:  Int J Numer Method Biomed Eng       Date:  2016-07-28       Impact factor: 2.747

3.  Biomechanical evaluation of the pathophysiologic developmental mechanisms of mitral valve prolapse: effect of valvular morphologic alteration.

Authors:  Ahnryul Choi; David D McPherson; Hyunggun Kim
Journal:  Med Biol Eng Comput       Date:  2015-08-26       Impact factor: 2.602

4.  Computational investigation of left ventricular hemodynamics following bioprosthetic aortic and mitral valve replacement.

Authors:  Fei Xu; Emily L Johnson; Chenglong Wang; Arian Jafari; Cheng-Hau Yang; Michael S Sacks; Adarsh Krishnamurthy; Ming-Chen Hsu
Journal:  Mech Res Commun       Date:  2020-10-16       Impact factor: 2.254

5.  Numerical Modeling of Intraventricular Flow during Diastole after Implantation of BMHV.

Authors:  Boyang Su; Foad Kabinejadian; Hui Qun Phang; Gideon Praveen Kumar; Fangsen Cui; Sangho Kim; Ru San Tan; Jimmy Kim Fatt Hon; John Carson Allen; Hwa Liang Leo; Liang Zhong
Journal:  PLoS One       Date:  2015-05-11       Impact factor: 3.240

6.  A finite strain nonlinear human mitral valve model with fluid-structure interaction.

Authors:  Hao Gao; Xingshuang Ma; Nan Qi; Colin Berry; Boyce E Griffith; Xiaoyu Luo
Journal:  Int J Numer Method Biomed Eng       Date:  2014-11-26       Impact factor: 2.747

7.  Synergy between Diastolic Mitral Valve Function and Left Ventricular Flow Aids in Valve Closure and Blood Transport during Systole.

Authors:  Vijay Govindarajan; John Mousel; H S Udaykumar; Sarah C Vigmostad; David D McPherson; Hyunggun Kim; Krishnan B Chandran
Journal:  Sci Rep       Date:  2018-04-18       Impact factor: 4.379

Review 8.  Heart blood flow simulation: a perspective review.

Authors:  Siamak N Doost; Dhanjoo Ghista; Boyang Su; Liang Zhong; Yosry S Morsi
Journal:  Biomed Eng Online       Date:  2016-08-25       Impact factor: 2.819

9.  Fully-coupled fluid-structure interaction simulation of the aortic and mitral valves in a realistic 3D left ventricle model.

Authors:  Wenbin Mao; Andrés Caballero; Raymond McKay; Charles Primiano; Wei Sun
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

Review 10.  Application of Patient-Specific Computational Fluid Dynamics in Coronary and Intra-Cardiac Flow Simulations: Challenges and Opportunities.

Authors:  Liang Zhong; Jun-Mei Zhang; Boyang Su; Ru San Tan; John C Allen; Ghassan S Kassab
Journal:  Front Physiol       Date:  2018-06-26       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.