Literature DB >> 2108548

A solution to the problem of high-flow jets from miniature angiographic catheters.

T B Daniel1, E W Akins, I F Hawkins.   

Abstract

In this study we evaluated methods for reducing high-flow jets from 5-French catheters that occur when injection pressures approach catheter tolerance (1000 psi [6.9 MPa]). This "jet effect" has been responsible for subintimal extravasation of contrast material in patients. We designed a physical model that accurately measures flow rates through the end hole and each side hole of 5-French high-flow catheters under simulated physiologic arterial pressure. When a standard catheter commonly used for injection of contrast material was studied, flow of contrast material was 34% through the end hole and 31% through the distal side-hole pair at high injection pressures (1000 psi). We examined the effect of altering the size and configuration of catheter side holes and end hole in an effort to create an improved flow profile, and thus a safer angiographic catheter. End-hole flow rate was reduced by 73% to 9% of total flow by tapering the 5-French catheter to 0.018 in. (0.046 cm) and by using smaller 0.015-in. (0.038-cm) side holes for even flow distribution. The high-flow jets present with standard high-flow 5-French catheters do not occur when flow-restrictive end holes and side holes are used. A uniform flow profile can be obtained without sacrificing delivery of contrast material through small catheters.

Entities:  

Mesh:

Year:  1990        PMID: 2108548     DOI: 10.2214/ajr.154.5.2108548

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Computational analysis of the effectiveness of blood flushing with saline injection from an intravascular diagnostic catheter.

Authors:  Narugopal Ghata; Ralph C Aldredge; Julien Bec; Laura Marcu
Journal:  Int J Numer Method Biomed Eng       Date:  2014-07-17       Impact factor: 2.747

2.  Influence of contrast-enhanced ultrasound administration setups on microbubble enhancement: a focus on pediatric applications.

Authors:  Michael R Kramer; Nishi Bhagat; Susan J Back; Laura Poznick; Flemming Forsberg; Kassa Darge; John R Eisenbrey
Journal:  Pediatr Radiol       Date:  2017-09-11

3.  More holes, more contrast? Comparing an 18-gauge non-fenestrated catheter with a 22-gauge fenestrated catheter for cardiac CT.

Authors:  Andreas Marco Fischer; Philipp Riffel; Thomas Henzler; U Joseph Schoepf; Andres F Abadia; Richard Robert Bayer; Holger Haubenreisser; Dante Giovagnoli; Alexander Kremer; Stefan O Schoenberg; Joshua Gawlitza
Journal:  PLoS One       Date:  2020-06-08       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.