Periprosthetic fractures of the humerus.

Andreas F Mavrogenis1, Andrea Angelini, Enrico Guerra, Panayiotis J Papagelopoulos, Pietro Ruggieri, Roberto Rotini.   

Abstract

Classifications have been previously reported and biomechanical studies have been performed, but the management of humeral fractures between implants remains problematic. At the time of arthroplasty, planning of the optimum length of the prostheses is required, especially for patients being considered for a second arthroplasty in the ipsilateral elbow or shoulder. Current treatment may be conservative if reduction can be obtained and the prostheses are stable, or it may be surgical using internal fixation with plates, strut grafts, double plates, or a plate and strut graft construct if the fracture extends around the components of the prosthesis and autogenous bone grafting.

Entities:  

Mesh:

Year:  2009        PMID: 21083536     DOI: 10.1615/jlongtermeffmedimplants.v19.i4.70

Source DB:  PubMed          Journal:  J Long Term Eff Med Implants        ISSN: 1050-6934


  1 in total

Review 1.  Past and present of the use of cerclage wires in orthopedics.

Authors:  Andrea Angelini; Concetto Battiato
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-04