Literature DB >> 21082180

Defining pseudoptosis (bottoming out) 3 years after short-scar medial pedicle breast reduction.

Michelle Quan1, Ahmed Fadl, Kevin Small, Oren Tepper, Naveen Kumar, Mihye Choi, Nolan Karp.   

Abstract

BACKGROUND: Pseudoptosis (bottoming out) is a well-observed phenomenon occurring after all types of breast reduction surgery. The authors' team previously reported the use of three-dimensional (3D) imaging to demonstrate that significant morphologic changes occur in the breast during the first year after short-scar medial pedicle breast reduction. This study extended this evaluation to postoperative year 3.
METHODS: Patients undergoing short-scar medial pedicle breast reduction had 3D photographs taken using the Canfield Vectra 3-pod system or the Konica Minolta V910 during postoperative follow-up visits at 1 month, 1 year, 2 years, and 3 years. Patients were assessed for pseudoptosis and breast morphologic changes using the 3D-based measurements.
RESULTS: During the 3 year period, 10 patients completed the study. The total breast volume decreased significantly during the first postoperative year by 20.6% (P < 0.05). No change in volume occurred during postoperative years 2 and 3 (P > 0.05). Pseudoptosis was documented in the first postoperative year by a 6% migration of breast tissue from the upper pole to the lower pole of the breast (P < 0.05), without significant change noted during the next 2 postoperative years (P > 0.05). This redistribution of the breast parenchyma correlated with a decrease in breast anteroposterior projection of 10.6 mm (P < 0.05) during the same period, with an insignificant change during postoperative years 2 and 3. During the first postoperative year, 3D comparative analysis recorded a 4.4-mm difference in the 3D topography (P < 0.05) and no further changes thereafter. The angle of breast projection showed a significant decrease of 17% (P < 0.05) in the first postoperative year and no change in subsequent years.
CONCLUSION: Three-dimensional photography is a useful tool enabling the plastic surgeon to monitor the postoperative changes in breast morphology objectively. This study provides quantifiable data demonstrating that pseudoptosis and tissue redistribution are limited to the initial postoperative year for patients undergoing short-scar medial pedicle breast reduction. The kinetic change in the breasts during postoperative years 2 and 3 appears to be minimal. Studies comparing the changes in morphology over time with different techniques of breast reduction are underway.

Entities:  

Mesh:

Year:  2010        PMID: 21082180     DOI: 10.1007/s00266-010-9615-6

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  4 in total

Review 1.  Breast volumetric analysis for aesthetic planning in breast reconstruction: a literature review of techniques.

Authors:  Michael P Chae; Warren Matthew Rozen; Robert T Spychal; David J Hunter-Smith
Journal:  Gland Surg       Date:  2016-04

2.  Myo-Glandular Flap Breast Reduction: Preventing the Bottoming out Deformity-A Novel Technique.

Authors:  Sadri O Sozer; Paul M Phillips
Journal:  Aesthetic Plast Surg       Date:  2021-03-03       Impact factor: 2.326

3.  A prospective analysis of dynamic loss of breast projection in tissue expander-implant reconstruction.

Authors:  Lauren M Mioton; Sumanas W Jordan; John Ys Kim
Journal:  Arch Plast Surg       Date:  2015-05-14

Review 4.  Longevity of ptosis correction in mastopexy and reduction mammaplasty: A systematic review of techniques.

Authors:  Ryan D Wagner; Jeffrey L Lisiecki; Michael V Chiodo; Rod J Rohrich
Journal:  JPRAS Open       Date:  2022-05-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.