Direct measurement of the instantaneous linewidth of rapidly wavelength-swept lasers.

Benjamin R Biedermann1, Wolfgang Wieser, Christoph M Eigenwillig, Thomas Klein, Robert Huber.   

Abstract

The instantaneous linewidth of rapidly wavelength-swept laser sources as used for optical coherence tomography (OCT) is of crucial interest for a deeper understanding of physical effects involved in their operation. Swept lasers for OCT, typically sweeping over ~15 THz in ~10 μs, have linewidths of several gigahertz. The high optical-frequency sweep speed makes it impossible to measure the instantaneous spectrum with standard methods. Hence, up to now, experimental access to the instantaneous linewidth was rather indirect by the inverse Fourier transform of the coherence decay. In this Letter, we present a method by fast synchronous time gating and extraction of a "snapshot" of the instantaneous spectrum with an electro-optic modulator, which can subsequently be measured with an optical spectrum analyzer. This new method is analyzed in detail, and systematic artifacts, such as sideband generation due to the modulation and residual wavelength uncertainty due to the sweeping operation, are quantified. The method is checked for consistency with results from the common, more indirect measurement via coherence properties.

Mesh:

Year:  2010        PMID: 21081979     DOI: 10.1364/OL.35.003733

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  5 in total

Review 1.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

2.  Picosecond pulses from wavelength-swept continuous-wave Fourier domain mode-locked lasers.

Authors:  Christoph M Eigenwillig; Wolfgang Wieser; Sebastian Todor; Benjamin R Biedermann; Thomas Klein; Christian Jirauschek; Robert Huber
Journal:  Nat Commun       Date:  2013       Impact factor: 14.919

3.  High-resolution retinal swept source optical coherence tomography with an ultra-wideband Fourier-domain mode-locked laser at MHz A-scan rates.

Authors:  Jan Philip Kolb; Tom Pfeiffer; Matthias Eibl; Hubertus Hakert; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-12-05       Impact factor: 3.732

4.  Parametric spectro-temporal analyzer (PASTA) for real-time optical spectrum observation.

Authors:  Chi Zhang; Jianbing Xu; P C Chui; Kenneth K Y Wong
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

5.  Joint aperture detection for speckle reduction and increased collection efficiency in ophthalmic MHz OCT.

Authors:  Thomas Klein; Raphael André; Wolfgang Wieser; Tom Pfeiffer; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-03-28       Impact factor: 3.732

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.