An x-ray image guidance system for small animal stereotactic irradiation.

K H Song1, R Pidikiti, S Stojadinovic, M Speiser, S Seliounine, D Saha, T D Solberg.   

Abstract

An x-ray image-guided small animal stereotactic irradiator was developed and characterized to enable tumor visualization and accurate target localization for small field, high dose irradiation. The system utilizes a custom collimation system, a motorized positioning system (x, y, θ), a digital imaging panel and operating software, and is integrated with a commercial x-ray unit. The essential characteristics of the irradiator include small radiation fields (1-10 mm), high dose rate (>10 Gy min(-1)) and submillimeter target localization. The software enables computer-controlled image acquisition, stage motion and target localization providing simple and precise automated target localization. The imaging panel was characterized in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and spatial resolution. Overall localization accuracy and precision were assessed. SNR, CNR and spatial resolution are 24 dB, 21 dB and 2.8 lp mm(-1), respectively, and localization accuracy is approximately 65 µm with 6 µm precision. With the aid of image guidance, system performance was subsequently used to evaluate radiation response in a rat orthotopic lung tumor effectively sparing normal tissues and in a mouse normal lung. The capabilities of 3D treatment and cone-beam computed tomography are presented for 3D localization and delivery as a work in progress.

Entities:  

Mesh:

Year:  2010        PMID: 21081818     DOI: 10.1088/0031-9155/55/23/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Novel technique for high-precision stereotactic irradiation of mouse brains.

Authors:  J Hartmann; J Wölfelschneider; C Stache; R Buslei; A Derer; M Schwarz; T Bäuerle; R Fietkau; U S Gaipl; C Bert; A Hölsken; B Frey
Journal:  Strahlenther Onkol       Date:  2016-07-11       Impact factor: 3.621

2.  Dentate gyrus neurogenesis ablation via cranial irradiation enhances morphine self-administration and locomotor sensitization.

Authors:  Sarah E Bulin; Matthew L Mendoza; Devon R Richardson; Kwang H Song; Timothy D Solberg; Sanghee Yun; Amelia J Eisch
Journal:  Addict Biol       Date:  2017-06-19       Impact factor: 4.280

3.  An experimental model-based exploration of cytokines in ablative radiation-induced lung injury in vivo and in vitro.

Authors:  Zhen-Yu Hong; Kwang Hyun Song; Joo-Heon Yoon; Jaeho Cho; Michael D Story
Journal:  Lung       Date:  2015-03-07       Impact factor: 2.584

4.  Image-guided cranial irradiation-induced ablation of dentate gyrus neurogenesis impairs extinction of recent morphine reward memories.

Authors:  Phillip D Rivera; Steven J Simmons; Ryan P Reynolds; Alanna L Just; Shari G Birnbaum; Amelia J Eisch
Journal:  Hippocampus       Date:  2019-02-18       Impact factor: 3.899

5.  Evaluation of On- and Off-Line Bioluminescence Tomography System for Focal Irradiation Guidance.

Authors:  Bin Zhang; John W Wong; Iulian I Iordachita; Juvenal Reyes; Katriana Nugent; Phuoc T Tran; Stephen W Tuttle; Constantinos Koumenis; Ken Kang-Hsin Wang
Journal:  Radiat Res       Date:  2016-11-21       Impact factor: 2.841

6.  Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.

Authors:  Steven T Bache; Titania Juang; Matthew D Belley; Bridget F Koontz; John Adamovics; Terry T Yoshizumi; David G Kirsch; Mark Oldham
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

7.  Image-Guided Radiotherapy Using a Modified Industrial Micro-CT for Preclinical Applications.

Authors:  Manuela C Felix; Jens Fleckenstein; Stefanie Kirschner; Linda Hartmann; Frederik Wenz; Marc A Brockmann; Gerhard Glatting; Frank A Giordano
Journal:  PLoS One       Date:  2015-05-19       Impact factor: 3.240

8.  MR-CBCT image-guided system for radiotherapy of orthotopic rat prostate tumors.

Authors:  Tsuicheng D Chiu; Tatsuya J Arai; James Campbell Iii; Steve B Jiang; Ralph P Mason; Strahinja Stojadinovic
Journal:  PLoS One       Date:  2018-05-30       Impact factor: 3.240

9.  Partial depletion of regulatory T cells does not influence the inflammation caused by high dose hemi-body irradiation.

Authors:  Shihong Ma; James A Richardson; Andrew Bitmansour; Timothy D Solberg; Rajesh Pidikiti; Kwang Song; Strahinja Stojadinovic; Ellen S Vitetta; Jeffrey J Meyer
Journal:  PLoS One       Date:  2013-02-11       Impact factor: 3.240

10.  An athymic rat model of cutaneous radiation injury designed to study human tissue-based wound therapy.

Authors:  Lucas H Rifkin; Strahinja Stojadinovic; Collin H Stewart; Kwang H Song; Michael C Maxted; Marcus H Bell; Natalie S Kashefi; Michael P Speiser; Michel Saint-Cyr; Michael D Story; Rod J Rohrich; Spencer A Brown; Timothy D Solberg
Journal:  Radiat Oncol       Date:  2012-05-08       Impact factor: 3.481

View more