Literature DB >> 21079353

Stability of a Ag/AgCl reference electrode equipped with an ionic liquid salt bridge composed of 1-methyl-3-octylimidazolium bis(trifluoromethanesulfonyl)-amide in potentiometry of pH standard buffers.

Manabu Shibata1, Mikito Yamanuki, Yasukazu Iwamoto, Satoshi Nomura, Takashi Kakiuchi.   

Abstract

The stability of a Ag/AgCl reference electrode equipped with a gelled ionic liquid, 1-methyl-3-octylimidazolium bis(trifluoromethanesulfonyl)amide (C(8)mimC(1)C(1)N), as a salt bridge, was examined in the potentiometry of pH standard solutions. The variation in the liquid junction potential (LJP) of the ionic liquid (IL)-type reference electrode, measured with respect to a double junction-type KCl reference electrode, was within 1 mV when one standard solution was replaced by another, except for the phthalate standard. The time course of the potential of the IL-type reference electrode showed a standard deviation of ±0.3 mV in all buffer solutions. The reproducible deviation of the potential of the IL-type reference electrode in the phthalate pH standard amounted to 5 mV. The deviation is due to the partition of the hydrogen phthalate in the C(8)mimC(1)C(1)N, influencing the phase boundary potential (PBP) across the interface between C(8)mimC(1)C(1)N and the phthalate standard. If a citrate standard is used instead of the phthalate buffer, the IL salt bridge works satisfactorily as a salt bridge for a reference electrode suitable for potentiometoric pH measurements.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21079353     DOI: 10.2116/analsci.26.1203

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  3 in total

Review 1.  Electrochemical sensors and biosensors.

Authors:  Danielle W Kimmel; Gabriel LeBlanc; Mika E Meschievitz; David E Cliffel
Journal:  Anal Chem       Date:  2011-11-11       Impact factor: 6.986

Review 2.  Recent progress in the development of improved reference electrodes for electrochemistry.

Authors:  Blair K Troudt; Celeste R Rousseau; Xin I N Dong; Evan L Anderson; Philippe Bühlmann
Journal:  Anal Sci       Date:  2022-02-28       Impact factor: 2.081

3.  A simple method for decreasing the liquid junction potential in a flow-through-type differential pH sensor probe consisting of pH-FETs by exerting spatiotemporal control of the liquid junction.

Authors:  Akira Yamada; Satoshi Mohri; Michihiro Nakamura; Keiji Naruse
Journal:  Sensors (Basel)       Date:  2015-04-01       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.