Literature DB >> 21078283

Analysis of two pharmacodynamic biomarkers using acoustic micro magnetic particles on the ViBE bioanalyzer.

Zhong-Hua Yan1, Lara L Madison, Anne Burkhardt, Jie Yu, Olga Tayber, Zhi Li, Dongyun Wu, Huay-Keng Loke, Deborah R Wysong, Natalia Iartchouk, Michael D Smith, Mike Kuranda, Ping Li, Michael E Bembenek.   

Abstract

Pharmacodynamic responses to drug treatment are often used to confirm drug-on-target biological responses. Methods ranging from mass spectrometry to immunohistochemistry exist for such analyses. By far, the most extensively used methodologies employ antigen-specific antibodies for detection (at a minimum) and, in some cases, target quantitation as well. Using a novel frequency-modulating technology from BioScale called acoustic micro magnetic particle (AMMP) detection, two pathway biomarkers were chosen for pharmacodynamic analysis and compared with either AlphaScreen or LI-COR Western blot assays. For these studies, pharmacodynamic biomarkers for both proteasome and phosphoinositol 3-kinase inhibition were used. Our results show clearly that the BioScale technology is a robust and rapid method for measuring recombinant standards or endogenously derived proteins from both tissue culture and mouse xenograft tumor lysates. Moreover, the sensitivity obtained with the BioScale platform compares favorably with LI-COR Western blot and AlphaScreen technologies. Furthermore, the use of the ViBE Bioanalyzer eliminates the labor-intensive effort of Western blot analysis and is devoid of the optical and other endogenous interfering substances derived from lysates of xenograft tumors typically observed with AlphaScreen. 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21078283     DOI: 10.1016/j.ab.2010.11.012

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  4 in total

1.  Good vibrations.

Authors:  Elie Dolgin
Journal:  Nat Med       Date:  2011-07-07       Impact factor: 53.440

2.  Evaluation of acoustic membrane microparticle (AMMP) technology for a sensitive ligand binding assay to support pharmacokinetic determinations of a biotherapeutic.

Authors:  Shannon D Chilewski; W Matthew Dickerson; Johanna R Mora; Ashley Saab; Edward M Alderman
Journal:  AAPS J       Date:  2014-09-23       Impact factor: 4.009

3.  Establishment of Patient-Derived Tumor Xenograft Models of Epithelial Ovarian Cancer for Preclinical Evaluation of Novel Therapeutics.

Authors:  Joyce F Liu; Sangeetha Palakurthi; Qing Zeng; Shan Zhou; Elena Ivanova; Wei Huang; Ioannis K Zervantonakis; Laura M Selfors; Yiping Shen; Colin C Pritchard; Mei Zheng; Vilmos Adleff; Eniko Papp; Huiying Piao; Marian Novak; Susan Fotheringham; Gerburg M Wulf; Jessie English; Paul T Kirschmeier; Victor E Velculescu; Cloud Paweletz; Gordon B Mills; David M Livingston; Joan S Brugge; Ursula A Matulonis; Ronny Drapkin
Journal:  Clin Cancer Res       Date:  2016-08-29       Impact factor: 12.531

4.  A Magnetic Bead-Based Sensor for the Quantification of Multiple Prostate Cancer Biomarkers.

Authors:  Jesse V Jokerst; Zuxiong Chen; Lingyun Xu; Rosalie Nolley; Edwin Chang; Breeana Mitchell; James D Brooks; Sanjiv S Gambhir
Journal:  PLoS One       Date:  2015-09-30       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.