Literature DB >> 21075377

The 3D trajectory of the body centre of mass during adult human walking: evidence for a speed-curvature power law.

Luigi Tesio1, Viviana Rota, Laura Perucca.   

Abstract

During straight walking, the body centre of mass (CM) follows a 3D figure-of-eight ("bow-tie") trajectory about 0.2 m long and with sizes around 0.05 m on each orthogonal axis. This was shown in 18 healthy adults walking at 0.3 to 1.4 ms⁻¹ on a force-treadmill (Tesio and Rota, 2008). Double integration of force signals can provide both the changes of mechanical energy of the CM and its 3D displacements (Tesio et al., 2010). In the same subjects, the relationship between the tangential speed of the CM, Vt, the curvature, C, and its inverse--the radius of curvature, r(c), were analyzed. A "power law" (PL) model was applied, i.e. logVt was regressed over logr(c). A PL is known to apply to the most various goal-directed planar movements (e.g. drawing), where the coefficient of logr(c), β, usually takes values around 13. When the PL was fitted to the whole dataset, β was 0.346 and variance explanation, R², was 59.8%. However, when the data were split into low- and high-curvature subsets (LC, HC, arbitrary cut-off of C=0.05 mm⁻¹, r(c)=20mm), β was 0.185 in the LC (R² 0.214) and 0.486 in the HC (R² 0.536) tracts. R² on the whole dataset increased to 0.763 if the LC-HC classification of the forward speed and their interaction entered the model. The β coefficient, the curvature C, and the pendulum-like recovery of mechanical energy were lower during the double foot-ground contact phase, compared to the single contact. Along the CM trajectory, curvature and muscle power output peaked together around the inversions of lateral direction. Non-zero torsion values were randomly distributed along 60% of the trajectory, suggesting that this is not segmented into piecewise planar tracts. It is proposed that the trajectory can be segmented into one tract that is more actively controlled (tie) where a PL fits poorly and another tract which is more ballistic (bow) where a PL fits well. Results need confirmation through more appropriate 3D PL modelling.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21075377     DOI: 10.1016/j.jbiomech.2010.10.035

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Gait measures with a triaxial accelerometer among patients with neurological impairment.

Authors:  Patrik Fazio; Gino Granieri; Ilaria Casetta; Edward Cesnik; Sante Mazzacane; Pietro Caliandro; Francesco Pedrielli; Enrico Granieri
Journal:  Neurol Sci       Date:  2012-03-25       Impact factor: 3.307

2.  Crouch gait can be an effective form of forced-use/no constraint exercise for the paretic lower limb in stroke.

Authors:  Luigi Tesio; Viviana Rota; Chiara Malloggi; Luigia Brugliera; Luigi Catino
Journal:  Int J Rehabil Res       Date:  2017-09       Impact factor: 1.479

Review 3.  The Motion of Body Center of Mass During Walking: A Review Oriented to Clinical Applications.

Authors:  Luigi Tesio; Viviana Rota
Journal:  Front Neurol       Date:  2019-09-20       Impact factor: 4.003

4.  Balance Impairment in Fahr's Disease: Mixed Signs of Parkinsonism and Cerebellar Disorder. A Case Study.

Authors:  Stefano Scarano; Viviana Rota; Luigi Tesio; Laura Perucca; Antonio Robecchi Majnardi; Antonio Caronni
Journal:  Front Hum Neurosci       Date:  2022-03-09       Impact factor: 3.169

5.  Knee rotationplasty: motion of the body centre of mass during walking.

Authors:  Viviana Rota; Maria Grazia Benedetti; Yusuke Okita; Marco Manfrini; Luigi Tesio
Journal:  Int J Rehabil Res       Date:  2016-12       Impact factor: 1.479

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.