Literature DB >> 21074929

Respiration indices and stability measurements of compost through electrolytic respirometry.

V Sánchez Arias1, F J Fernández, L Rodríguez, J Villaseñor.   

Abstract

An experimental technique for compost stability measurements based on Sapromat electrolytic respirometry was optimised and subsequently applied to a sludge composting process. Anaerobically digested sewage sludge mixed with reed was composted during 90 days in a pilot-scale rotary drum with forced aeration. Periodic solid samples were taken, and a previously optimised respirometric procedure was applied in order to measure the oxygen consumption. The respirometric experiments were made directly with a few grams of solid samples, optimum moisture and 37 °C over a period of 96 h. The results obtained showed how the respiration activity of the sludge decreased during the composting experiment under the specific operating conditions. The specific oxygen uptake rate (SOUR) instant values from the oxygen consumption curves were obtained, and two commonly used respirometric indexes (RI(24) and AT(4)) were calculated for all samples. Both RI(24) (a mean of the SOUR values during the 24 h maximum activity period) and AT(4) (total oxygen consumption after 4 days) were the recommended parameters for the estimation of compost stability by the European Union in the second draft of the Working Document on the Biological Treatment of Biowaste in 2001. Both indexes exponentially decreased with the composting time, and a good linear correlation between them was observed. Final values of RI(24) and AT(4) after 90 days were 600 mg O(2) kg VS(-1) h(-1) and 26 mg O(2) gTS(-1), respectively. We also considered if this technique could be classified as a Dynamic or Static method, the two primary respirometric techniques for measuring compost stability. Supposing that the proposed procedure is considered a dynamic method (no limitations on the amount of oxygen supply), the final RI(24) obtained was compared with the dynamic respiration index (DRI) proposed by the EU (1000 mg O(2) kg VS(-1) h(-1)). Our result indicated that stable compost was obtained after 90 d. However, if a static limit was considered (AT(4) lower than 10 mg O(2) gTS(-1) as proposed by the EU), our result would indicate that more residence composting time would be needed. Taking into account these results, the advantages and disadvantages and the validity of the proposed method are discussed.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21074929     DOI: 10.1016/j.jenvman.2010.10.053

Source DB:  PubMed          Journal:  J Environ Manage        ISSN: 0301-4797            Impact factor:   6.789


  1 in total

1.  Portable and Low-Cost Respirometric Microsystem for the Static and Dynamic Respirometry Monitoring of Compost.

Authors:  Juliette F Bermudez; Juan F Saldarriaga; Johann F Osma
Journal:  Sensors (Basel)       Date:  2019-09-24       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.