Literature DB >> 21071742

Total corneal power estimation: ray tracing method versus gaussian optics formula.

Li Wang1, Ashraf M Mahmoud, Betty Lise Anderson, Douglas D Koch, Cynthia J Roberts.   

Abstract

PURPOSE: To evaluate with the use of corneal topographic data the differences between total corneal power calculated using ray tracing (TCP) and the Gaussian formula (GEP) in normal eyes, eyes that previously underwent laser in situ keratomileusis/photorefractive keratectomy (LASIK/PRK), and theoretical models.
METHODS: TCP and GEP using mean instantaneous curvature were calculated over the central 4-mm zone in 94 normal eyes, 61 myopic-LASIK/PRK eyes, and 9 hyperopic-LASIK/PRK eyes. A corneal model was constructed to assess the incident angles at the posterior corneal surface for both refracted rays and parallel rays. Corneal models with varying parameters were also constructed to investigate the differences between mean TCP and GEP (4-mm zone), and an optical design software validation was performed.
RESULTS: The TCP values tended to be less than GEP in normal and myopic-LASIK/PRK eyes, with the opposite relationship in some hyperopic-LASIK/PRK eyes having the highest anterior surface curvature. The difference between TCP and GEP was a function of anterior surface instantaneous radii of curvature and posterior/anterior ratio in postrefractive surgery eyes but not in normal eyes. In model corneas, posterior incident angles with parallel rays were greater than those with refracted rays, producing an overestimation of negative effective posterior corneal power; differences in magnitude between TCP and GEP increased with decreasing ratio of posterior/anterior radii of curvature, consistent with clinical results.
CONCLUSIONS: In eyes after refractive surgery, calculating posterior corneal power using the Gaussian formula and its paraxial assumptions introduces errors in the calculation of total corneal power. This may generate errors in intraocular lens power calculation when using the Gaussian formula after refractive surgery.

Entities:  

Mesh:

Year:  2011        PMID: 21071742     DOI: 10.1167/iovs.09-4982

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  27 in total

1.  Bio-orthogonally crosslinked hyaluronate-collagen hydrogel for suture-free corneal defect repair.

Authors:  Fang Chen; Peter Le; Gabriella M Fernandes-Cunha; Sarah C Heilshorn; David Myung
Journal:  Biomaterials       Date:  2020-06-10       Impact factor: 12.479

2.  Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes.

Authors:  Yanjun Hua; Chao Pan; Qinmei Wang
Journal:  Int Ophthalmol       Date:  2019-03-01       Impact factor: 2.031

3.  Accuracy of corneal astigmatism correction with two Barrett Toric calculation methods.

Authors:  Jun Yang; Hong Zhang; Xiao-Tong Yang; Fang Tian; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

4.  Simultaneous Interpenetrating Polymer Network of Collagen and Hyaluronic Acid as an In Situ-Forming Corneal Defect Filler.

Authors:  Fang Chen; Peter Le; Krystal Lai; Gabriella M Fernandes-Cunha; David Myung
Journal:  Chem Mater       Date:  2020-05-27       Impact factor: 9.811

5.  Predictability of pseudophakic refraction using patient-customized paraxial eye models.

Authors:  Yu-Cherng Chang; Florence Cabot; Bianca Maceo Heilman; Larissa Meza; Marco Ruggeri; Arthur Ho; Sonia H Yoo; Jean-Marie Parel; Fabrice Manns
Journal:  J Cataract Refract Surg       Date:  2022-09-01       Impact factor: 3.528

6.  The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements.

Authors:  Youngsub Eom; Su-Yeon Kang; Hyo Myung Kim; Jong Suk Song
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-07-20       Impact factor: 3.117

7.  Distributed scanning volumetric SDOCT for motion corrected corneal biometry.

Authors:  Ryan P McNabb; Francesco Larocca; Sina Farsiu; Anthony N Kuo; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2012-08-10       Impact factor: 3.732

8.  Corneal biometry from volumetric SDOCT and comparison with existing clinical modalities.

Authors:  Anthony N Kuo; Ryan P McNabb; Mingtao Zhao; Francesco Larocca; Sandra S Stinnett; Sina Farsiu; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2012-05-08       Impact factor: 3.732

9.  Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.

Authors:  Kaevalin Lekhanont; Manachai Nonpassopon; Khemruetai Wannarosapark; Varintorn Chuckpaiwong
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

10.  Keratometric index obtained by Fourier-domain optical coherence tomography.

Authors:  Yanjun Hua; Aleksander Stojanovic; Tor Paaske Utheim; Xiangjun Chen; Sten Ræder; Jinhai Huang; Qinmei Wang
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.