Literature DB >> 21071246

Characterization of a 3D MEMS fabricated micro-solenoid at 9.4 T.

M Mohmmadzadeh1, N Baxan, V Badilita, K Kratt, H Weber, J G Korvink, U Wallrabe, J Hennig, D von Elverfeldt.   

Abstract

We present for the first time a complete characterization of a micro-solenoid for high resolution MR imaging of mass- and volume-limited samples based on three-dimensional B(0), B(1) per unit current (B(1)(unit)) and SNR maps. The micro-solenoids are fabricated using a fully micro-electromechanical systems (MEMS) compatible process in conjunction with an automatic wire-bonder. We present 15 μm isotropic resolution 3D B(0) maps performed using the phase difference method. The resulting B(0) variation in the range of [-0.07 ppm to -0.157 ppm] around the coil center, compares favorably with the 0.5 ppm limit accepted for MR microscopy. 3D B(1)(unit) maps of 40 μm isotropic voxel size were acquired according to the extended multi flip angle (ExMFA) method. The results demonstrate that the characterized microcoil provides a high and uniform sensitivity distribution around its center (B(1)(unit) = 3.4 mT/A ± 3.86%) which is in agreement with the corresponding 1D theoretical data computed along the coil axis. The 3D SNR maps reveal a rather uniform signal distribution around the coil center with a mean value of 53.69 ± 19%, in good agreement with the analytical 1D data along coil axis in the axial slice. Finally, we prove the microcoil capabilities for MR microscopy by imaging Eremosphaera viridis cells with 18 μm isotropic resolution.
Copyright © 2010. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21071246     DOI: 10.1016/j.jmr.2010.09.021

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  2 in total

1.  Microfabricated inserts for magic angle coil spinning (MACS) wireless NMR spectroscopy.

Authors:  Vlad Badilita; Birgit Fassbender; Kai Kratt; Alan Wong; Christian Bonhomme; Dimitris Sakellariou; Jan G Korvink; Ulrike Wallrabe
Journal:  PLoS One       Date:  2012-08-20       Impact factor: 3.240

2.  Heteronuclear Micro-Helmholtz Coil Facilitates µm-Range Spatial and Sub-Hz Spectral Resolution NMR of nL-Volume Samples on Customisable Microfluidic Chips.

Authors:  Nils Spengler; Jens Höfflin; Ali Moazenzadeh; Dario Mager; Neil MacKinnon; Vlad Badilita; Ulrike Wallrabe; Jan G Korvink
Journal:  PLoS One       Date:  2016-01-05       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.