Literature DB >> 21070181

Application of a new dosimetry program TAOCS to assess transient vapour absorption in the upper airways.

Geng Tian1, P Worth Longest.   

Abstract

Most previous models of vapour absorption in the respiratory tract have assumed steady state flow fields and steady state diffusion into the airway walls. However, recent studies have shown that transient absorption flux into the walls of the upper airways can significantly influence predicted uptake or deposition values. The disadvantage of accounting for transient absorption into the airway walls is a more complex boundary condition and numerical model. The objective of this study was to evaluate the effects of both transient flow fields and transient mass absorption on the uptake of highly and moderately soluble compounds in an upper airway model. The geometry consisted of the mouth-throat region coupled with a multilayer wall model containing air, mucus, tissue, and blood phases. Based on previous studies, a boundary condition that represents transient absorption into the airway walls was applied. A new dosimetry program, named transient absorption of chemical species (TAOCS) 1.0, was developed and implemented to determine the coefficients needed for the transient boundary condition expression and to apply the boundary condition to the computational fluid dynamics (CFD) model. Both steady state and transient conditions were considered for the airflow field and wall absorption. The case of perfect wall absorption with a zero surface concentration was also considered. Results indicated that steady state airflow provided a reasonable approximation to transient airflow conditions in terms of total and local deposition (values within 10-30%). However, the simulation of transient wall absorption was critical unless the compound was highly soluble (with a mucus-air partition coefficient ≥320), in which case a perfect absorption boundary condition was accurate to within a relative difference of 50%. Still, the perfect absorption boundary condition did not accurately capture local deposition enhancement factor values. Based on these findings, implementation of the transient absorption boundary condition appears critical to predict local deposition characteristics for even highly soluble compounds. Use of the TAOCS program simplified the implementation of the complex transient absorption condition making the CFD simulation process more efficient and user-friendly.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21070181     DOI: 10.3109/08958378.2010.521783

Source DB:  PubMed          Journal:  Inhal Toxicol        ISSN: 0895-8378            Impact factor:   2.724


  6 in total

1.  Comparative Risks of Aldehyde Constituents in Cigarette Smoke Using Transient Computational Fluid Dynamics/Physiologically Based Pharmacokinetic Models of the Rat and Human Respiratory Tracts.

Authors:  Richard A Corley; Senthil Kabilan; Andrew P Kuprat; James P Carson; Richard E Jacob; Kevin R Minard; Justin G Teeguarden; Charles Timchalk; Sudhakar Pipavath; Robb Glenny; Daniel R Einstein
Journal:  Toxicol Sci       Date:  2015-04-08       Impact factor: 4.849

2.  Small Airway Absorption and Microdosimetry of Inhaled Corticosteroid Particles after Deposition.

Authors:  P Worth Longest; Michael Hindle
Journal:  Pharm Res       Date:  2017-06-22       Impact factor: 4.200

3.  In situ casting and imaging of the rat airway tree for accurate 3D reconstruction.

Authors:  Richard E Jacob; Sean M Colby; Senthil Kabilan; Daniel R Einstein; James P Carson
Journal:  Exp Lung Res       Date:  2013-06-20       Impact factor: 2.459

4.  Secondary indoor air pollution and passive smoking associated with cannabis smoking using electric cigarette device-demonstrative in silico study.

Authors:  Kazuki Kuga; Kazuhide Ito; Wenhao Chen; Ping Wang; Jeff Fowles; Kazukiyo Kumagai
Journal:  PLoS Comput Biol       Date:  2021-05-13       Impact factor: 4.475

5.  Absorption and Clearance of Pharmaceutical Aerosols in the Human Nose: Development of a CFD Model.

Authors:  Alex Rygg; P Worth Longest
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2016-01-29       Impact factor: 2.849

6.  Molecular Binding Contributes to Concentration Dependent Acrolein Deposition in Rat Upper Airways: CFD and Molecular Dynamics Analyses.

Authors:  Jinxiang Xi; Qin Hu; Linlin Zhao; Xiuhua April Si
Journal:  Int J Mol Sci       Date:  2018-03-27       Impact factor: 5.923

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.