Literature DB >> 21067938

Effect of fiducial configuration on target registration error in image-guided cranio-maxillofacial surgery.

Wenbin Zhang1, Chenhao Wang, Hongbo Yu, Yuncai Liu, Guofang Shen.   

Abstract

OBJECTIVE: To investigate the effect of the configuration of fiducials on target registration error (TRE) and test the accuracy of theoretical model of TRE prediction in image-guided cranio-maxillofacial surgery.
METHODS: A skull specimen was prepared with 20 titanium microscrews placed at defined locations and scanned with a 64-slice spiral computed tomography unit. These markers were separated into a registration fiducial group and a target fiducial group. An optical tracking system was used to perform skull-to-image registration procedures. Subsequent to each registration, the TRE was calculated by the navigation system. Each configuration registration was performed 50 times and the average was regarded as TRE of the configuration. The TRE prediction was also calculated for each configuration.
RESULTS: The TRE ranged from 0.58 mm to 3.88 mm. Relatively smaller values of TRE may be achieved by placing a majority of fiducials on the maxillary alveolus in proximity to the target and placing a small number on the cranium contralaterally. The TRE values are always larger than the corresponding TRE prediction but there is a high correlation between them.
CONCLUSION: The configuration of fiducials is an important factor in minimizing TRE and the TRE prediction is a good guide for fiducial marker placement.
Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Mesh:

Year:  2010        PMID: 21067938     DOI: 10.1016/j.jcms.2010.10.008

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  4 in total

1.  Marker-free registration for the accurate integration of CT images and the subject's anatomy during navigation surgery of the maxillary sinus.

Authors:  S-H Kang; M-K Kim; J-H Kim; H-K Park; W Park
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  Minimization of target registration error for vertebra in image-guided spine surgery.

Authors:  Marzieh Ershad; Alireza Ahmadian; Nassim Dadashi Serej; Hooshang Saberi; Keyvan Amini Khoiy
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-03       Impact factor: 2.924

3.  Application of computer-assisted navigation in mandibular angle osteotomy.

Authors:  Liqin Lin; Bokai Fan; Zheyuan Yu; Liang Xu; Jie Yuan; Jun Wu; Min Wei
Journal:  J Int Med Res       Date:  2019-06-17       Impact factor: 1.671

4.  Comparative Study of Two Pose Measuring Systems Used to Reduce Robot Localization Error.

Authors:  Marek Franaszek; Geraldine S Cheok; Jeremy A Marvel
Journal:  Sensors (Basel)       Date:  2020-02-28       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.