Literature DB >> 21067467

Human lymphocyte activation assay: an in vitro method for predictive immunotoxicity testing.

Mark Collinge1, Susan H Cole, Patricia A Schneider, Carol B Donovan, Cris Kamperschroer, Thomas T Kawabata.   

Abstract

Preclinical immunotoxicity assessments may be performed during pharmaceutical drug development in order to identify potential cause for concern prior to use in the clinic. The in vivo T-dependent antibody response (TDAR) is widely used in this regard, given its sensitivity to known immunosuppressive compounds, but may be impractical early in drug development where quantities of test article are limited. The goal of the current work is to develop an in vitro human cell-based assay that is sensitive to immunosuppression, uses relatively small quantities of test article, and is simple to perform with moderate to high throughput. Ideally, this assay would require the cooperation of multiple cellular compartments to produce a response, similar to the TDAR. Although the Mishell-Dutton assay (in vitro mouse splenic sheep red blood cell response) has been used for this purpose, it shows considerable inter-laboratory variability, and rodent cells are used which leads to potential difficulty in translation of findings to humans. We have developed an assay that measures an influenza antigen-specific response using frozen-stored human peripheral blood mononuclear cells, which we have termed the human lymphocyte activation (HuLA) assay. The HuLA assay is sensitive to cyclosporine, dexamethasone, rapamycin, mycophenolic acid, and methotrexate at concentrations within their respective therapeutic ranges. Although proliferation is the primary endpoint, we demonstrate that flow cytometry approaches may be used to characterize the proliferating lymphocyte subsets. Flu antigen-specific proliferation in the HuLA assay primarily involves both CD4+ and CD8+ T-lymphocytes and B-lymphocytes, although other lymphocyte subsets also proliferate. In addition, flu-specific antibody-secreting cells can be measured in this assay by ELISPOT, a response that is also sensitive to known immunosuppressive compounds. The HuLA assay represents a relatively straightforward assay with the capability of detecting immune suppression in human cells and can be applied to compound ranking and immunotoxicity assessment.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21067467     DOI: 10.3109/1547691X.2010.523881

Source DB:  PubMed          Journal:  J Immunotoxicol        ISSN: 1547-691X            Impact factor:   3.000


  2 in total

1.  Development and Use a Novel combined in-vivo and in-vitro Assay for Anti-inflammatory and Immunosuppressive Agents.

Authors:  Tan Li; Hong Chen; Xin Mei; Na Wei; Bo Cao
Journal:  Iran J Pharm Res       Date:  2013       Impact factor: 1.696

2.  Beyond AOPs: A Mechanistic Evaluation of NAMs in DART Testing.

Authors:  Ramya Rajagopal; Maria T Baltazar; Paul L Carmichael; Matthew P Dent; Julia Head; Hequn Li; Iris Muller; Joe Reynolds; Kritika Sadh; Wendy Simpson; Sandrine Spriggs; Andrew White; Predrag Kukic
Journal:  Front Toxicol       Date:  2022-03-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.