Literature DB >> 21062228

Development of a candidate secondary reference procedure (immunoassay based measurement procedure of higher metrological order) for cardiac troponin I: I. Antibody characterization and preliminary validation.

James E Noble1, David M Bunk, Robert H Christenson, Kenneth D Cole, Hua-Jun He, Alexei G Katrukha, Mauro Panteghini, Robert A Porter, Heinz Schimmel, Jillian R Tate, Lili Wang.   

Abstract

In this study, the first steps in the development of a secondary reference measurement procedure (RMP) 'higher metrological order measurement procedure' to support the cardiac troponin I (cTnI) standardization initiative is described. The RMP should be used to assign values to serum-based secondary reference materials (RMs) without analytical artifacts causing bias. A multiplexed bead-based assay and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) were used to identify the optimum monoclonal antibody pair (clones 560 and 19C7) for the RMP. Using these antibodies, an ELISA-based procedure was developed to accurately measure the main cTnI forms present in blood. The proposed RMP appears to show no bias when tested on samples containing various troponin complexes, phosphorylated and dephosphorylated forms, and heparin. The candidate assay displayed suitable linearity and sensitivity (limit of detection, 0.052 μg/L) for the measurement of the proposed cTnI secondary RMs. Preliminary comparison data on patient samples with a commercial cTnI assay are also provided to support the suitability of RMP for value assignment to RMs. Full validation and final assessment of the RMP will be performed through transferability and inter-comparison studies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21062228     DOI: 10.1515/CCLM.2010.316

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  4 in total

1.  Recommendations for Selection and Characterization of Protein Biomarker Assay Calibrator Material.

Authors:  Kyra J Cowan; Lakshmi Amaravadi; Mark J Cameron; Damien Fink; Darshana Jani; Medha Kamat; Lindsay King; Robert J Neely; Yan Ni; Paul Rhyne; Renee Riffon; Yuda Zhu
Journal:  AAPS J       Date:  2017-10-02       Impact factor: 4.009

2.  Quantification of cardiac troponin I in human plasma by immunoaffinity enrichment and targeted mass spectrometry.

Authors:  Nicole A Schneck; Karen W Phinney; Sang Bok Lee; Mark S Lowenthal
Journal:  Anal Bioanal Chem       Date:  2018-03-01       Impact factor: 4.142

3.  Commutability of possible external quality assessment materials for cardiac troponin measurement.

Authors:  Shunli Zhang; Jie Zeng; Chuanbao Zhang; Yilong Li; Haijian Zhao; Fei Cheng; Songlin Yu; Mo Wang; Wenxiang Chen
Journal:  PLoS One       Date:  2014-07-07       Impact factor: 3.240

4.  Towards Quantitative and Standardized Serological and Neutralization Assays for COVID-19.

Authors:  Linhua Tian; Elzafir B Elsheikh; Paul N Patrone; Anthony J Kearsley; Adolfas K Gaigalas; Sarah Inwood; Sheng Lin-Gibson; Dominic Esposito; Lili Wang
Journal:  Int J Mol Sci       Date:  2021-03-08       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.