Literature DB >> 21061358

In vitro study on Zr-based bulk metallic glasses as potential biomaterials.

Y B Wang1, Y F Zheng, S C Wei, M Li.   

Abstract

With pure Ti and pure Zr as controls, the corrosion resistance, ion release behavior, and in vitro biocompatibility of Be-containing Zr₄₁Ti₁₄Cu₁₂Ni₁₀Be₂₃ bulk metallic glass (BMG) (LM1), Zr₄₄Ti₁₁Cu₁₀Ni₁₀Be₂₅ BMG (LM1b), and Be-free Zr₅₇Nb₅Cu₁₅.₄Ni₁₂.₆Al₁₀ BMG (LM106) were investigated in terms of electrochemical measurements in simulated body fluid (SBF) with pH value 7.4 and artificial saliva (AS) with pH value 6.3, and 3-[4,4-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide (MTT) assay using L929 and NIH3T3 cells, aiming to assess the feasibility of Zr-based BMGs as potential biomaterial. It was found that LM1b showed superior corrosion resistance to LM106 and LM1 in both SBF and AS, and comparable with pure Ti and pure Zr. After 7200 s immersion, a two-layer structure oxide film was formed on LM1, LM1b, and pure Zr surfaces, while one-layer structure oxide film was formed on LM106 and pure Ti surfaces. The pitting corrosion potentials of LM1b were much higher than that of LM1, LM106, and pure Zr, resulting in very few ions releasing into the electrolytes. No Be ion could be detected but a little amount of Cu ion was detected for LM106, LM1, and LM1b after immersion in Dulbecco's modified Eagle's medium for 72 h at 37 °C. The indirect cytotoxicity results show that LM106, LM1, and LM1b extracts had no cytotoxicity to L929 and NIH3T3 cells. The direct cytotoxicity results show that cells could adhere well on the Zr-based BMG surface as in pure Ti and Zr. Lower cell proliferation rate of LM106 and LM1 is observed when compared with LM1b, which was found to be caused by Cu ion releasing rather than by Be ion.
© 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21061358     DOI: 10.1002/jbm.b.31725

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  5 in total

1.  In vitro biocompatibility assessment of Ti40Cu38Zr10Pd12 bulk metallic glass.

Authors:  A Blanquer; E Pellicer; A Hynowska; L Barrios; E Ibáñez; M D Baró; J Sort; C Nogués
Journal:  J Mater Sci Mater Med       Date:  2014-01       Impact factor: 3.896

2.  Nanostructured Zr-Pd metallic glass thin film for biochemical applications.

Authors:  Sergey V Ketov; Xuetao Shi; Guoqiang Xie; Ryotaro Kumashiro; Alexander Yu Churyumov; Andrey I Bazlov; Na Chen; Yoshifumi Ishikawa; Naoki Asao; Hongkai Wu; Dmitri V Louzguine-Luzgin
Journal:  Sci Rep       Date:  2015-01-15       Impact factor: 4.379

3.  The cytotoxic effect of TiF4 and NaF on fibroblasts is influenced by the experimental model, fluoride concentration and exposure time.

Authors:  Priscila Maria Aranda Salomão; Flávia Amadeu de Oliveira; Paula Danielle Rodrigues; Luana Polioni Al-Ahj; Kellen Cristina da Silva Gasque; Pia Jeggle; Marilia Afonso Rabelo Buzalaf; Rodrigo Cardoso de Oliveira; John Michael Edwardson; Ana Carolina Magalhães
Journal:  PLoS One       Date:  2017-06-14       Impact factor: 3.240

4.  On the Potential of Bulk Metallic Glasses for Dental Implantology: Case Study on Ti40Zr10Cu36Pd14.

Authors:  Alethea Liens; Aurélien Etiemble; Pascaline Rivory; Sandra Balvay; Jean-Marc Pelletier; Sandrine Cardinal; Damien Fabrègue; Hidemi Kato; Philippe Steyer; Tais Munhoz; Jerome Adrien; Nicolas Courtois; Daniel J Hartmann; Jérôme Chevalier
Journal:  Materials (Basel)       Date:  2018-02-06       Impact factor: 3.623

5.  Improving the Tribological Properties and Biocompatibility of Zr-Based Bulk Metallic Glass for Potential Biomedical Applications.

Authors:  Victoria Sawyer; Xiao Tao; Huan Dong; Behnam Dashtbozorg; Xiaoying Li; Rachel Sammons; Han-Shan Dong
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.