Literature DB >> 21059998

A new solar-powered blood pressure measuring device for low-resource settings.

Gianfranco Parati1, Michael Ochan Kilama, Andrea Faini, Elisa Facelli, Kenneth Ochen, Cyprian Opira, Shanthi Mendis, Jiguang Wang, Neil Atkins, Eoin O'Brien.   

Abstract

The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to predetermined criteria and to demonstrate the suitability of the device for low resource settings. A device, which fulfilled stipulated criteria in being inexpensive, semiautomated, and solar powered, was validated according to the International Protocol of the European Society of Hypertension; it was then subjected to field testing in 716 subjects from 2 centers in Uganda and 1 in Zambia. The Omron HEM-SOLAR having previously fulfilled accuracy criteria of the International Protocol for both systolic blood pressure (SBP) and diastolic blood pressure (DBP), fulfilled criteria for SBP, but not for DBP, when revalidated. In field testing, average SBPs and DBPs were 120.5 ± 21.6/74.6 ± 13.8 mm Hg and 122.3 ± 21.8/71.2 ± 14.0 mm Hg, respectively, with the auscultatory technique and the Omron HEM-SOLAR, respectively. Between-device agreement in defining SBP was 93.7%. The Omron HEM-SOLAR was favored over the mercury sphygmomanometer by both patients and investigators. In summary, considering the accuracy, robustness, relatively low cost, operational simplicity, and advantages such as solar power, the Omron HEM-SOLAR is likely to be a valuable device for improving BP measurement in low-resource settings with nonphysician health workers.

Entities:  

Mesh:

Year:  2010        PMID: 21059998     DOI: 10.1161/HYPERTENSIONAHA.110.160408

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  13 in total

Review 1.  Medical devices and diagnostics for cardiovascular diseases in low-resource settings.

Authors:  Helen McGuire; Bernhard H Weigl
Journal:  J Cardiovasc Transl Res       Date:  2014-10-08       Impact factor: 4.132

Review 2.  Neurocritical care in developing countries.

Authors:  Farrah J Mateen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 3.  Out-of-office blood pressure improves risk stratification in normotension and prehypertension people.

Authors:  Kei Asayama; Jana Brguljan-Hitij; Yutaka Imai
Journal:  Curr Hypertens Rep       Date:  2014-10       Impact factor: 5.369

4.  One-year routine opportunistic screening for hypertension in formal medical settings and potential improvements in hypertension awareness among older persons in developing countries: evidence from the Study on Global Ageing and Adult Health (SAGE).

Authors:  Jürgen Maurer; Alejandra Ramos
Journal:  Am J Epidemiol       Date:  2014-12-29       Impact factor: 4.897

Review 5.  Point-of-care diagnostics to improve maternal and neonatal health in low-resource settings.

Authors:  Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum
Journal:  Lab Chip       Date:  2017-10-11       Impact factor: 6.799

6.  Problems and Solutions in Implementing the World Hypertension League Recommendations for Automated Office Assessment of Blood Pressure.

Authors:  Eugenia V Veiga; Ana C Q G Daniel; Luiz A Bortolloto; Carlos A Machado; Frida L Plavinik; Maria CláudiaIrigoyen; Norm Campbell; John Kenerson; Lyne Cloutier
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-10-12       Impact factor: 3.738

7.  The Search for High-Impact Diagnostic and Management Tools for Low- and Middle-Income Countries: A Self-Powered Low-Cost Blood Pressure Measurement Device Powered by a Solid-State Vibration Energy Harvester.

Authors:  Onur Bilgen; John G Kenerson; Muge Akpinar-Elci; Rebecca Hattery; Lisbet M Hanson
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-04-24       Impact factor: 3.738

Review 8.  Policy statement of the world hypertension league on noninvasive blood pressure measurement devices and blood pressure measurement in the clinical or community setting.

Authors:  Norm R C Campbell; Adel E Berbari; Lyne Cloutier; Mark Gelfer; John G Kenerson; Tej K Khalsa; Daniel T Lackland; Daniel Lemogoum; Birinder K Mangat; Sailesh Mohan; Martin G Myers; Mark L Niebylski; Eoin O'Brien; George S Stergiou; Eugenia Velludo VeIga; Xin-Hua Zhang
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-05-08       Impact factor: 3.738

9.  Hypertension and diabetes: entry points for prevention and control of the global cardiovascular epidemic.

Authors:  Shanthi Mendis; Eoin O'Brien; Yackoob Kassim Seedat; Salim Yusuf
Journal:  Int J Hypertens       Date:  2013-04-07       Impact factor: 2.420

Review 10.  Need for better blood pressure measurement in developing countries to improve prevention of cardiovascular disease.

Authors:  Pietro Amedeo Modesti; Eleonora Perruolo; Gianfranco Parati
Journal:  J Epidemiol       Date:  2014-11-22       Impact factor: 3.211

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.