Literature DB >> 2105924

Influence of hip prostheses on high energy photon dose distributions.

C H Sibata1, H C Mota, P D Higgins, D Gaisser, J P Saxton, K H Shin.   

Abstract

Radiotherapy treatment of patients having a hip prosthesis is a common problem facing dosimetrists and physicists when the treatment plan requires irradiation of the pelvic area. To quantify the perturbation of these devices, attenuation studies were done with 6 and 18 MV photon beams using various hip prostheses models with varying size and composition. These studies have shown that an attenuation of as much as 50% can be found in a single beam profile under the prosthesis. We have studied the capability of a dose planning system to predict the transmission of these devices as compared with measurements.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2105924     DOI: 10.1016/0360-3016(90)90115-z

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

Review 1.  Fiducial marker guided prostate radiotherapy: a review.

Authors:  Angela G M O'Neill; Suneil Jain; Alan R Hounsell; Joe M O'Sullivan
Journal:  Br J Radiol       Date:  2016-09-23       Impact factor: 3.039

2.  Feasibility of concurrent treatment with the scanning ultrasound reflector linear array system (SURLAS) and the helical tomotherapy system.

Authors:  José A Peñagarícano; Eduardo Moros; Petr Novák; Yulong Yan; Peter Corry
Journal:  Int J Hyperthermia       Date:  2008-08       Impact factor: 3.914

3.  Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis.

Authors:  Nicholas Ade; F C P du Plessis
Journal:  J Appl Clin Med Phys       Date:  2017-07-25       Impact factor: 2.102

4.  Study of dosimetric properties of flattened and unflattened megavoltage x ray beam on high Z implant materials.

Authors:  Tamilarasan Rajamanickam; Sivakumar Muthu; Perumal Murugan; Muddappa Pathokonda; Krishnamoorthy Senthilnathan; Narayanasamy Arunai Nambi Raj; Padmanabhan Ramesh Babu
Journal:  J Appl Clin Med Phys       Date:  2018-09-28       Impact factor: 2.102

5.  Effect of Hip Prosthesis on Photon Beam Characteristics in Radiological Physics.

Authors:  Manindra Bhushan; Deepak Tripathi; Girigesh Yadav; Lalit Kumar; Abhinav Dewan; Gourav Kumar
Journal:  Asian Pac J Cancer Prev       Date:  2020-06-01

6.  A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac.

Authors:  Mohammad Taghi Bahreyni Toossi; Marziyeh Behmadi; Mahdi Ghorbani; Hamid Gholamhosseinian
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

7.  Dose uncertainties associated with a set density override of unknown hip prosthetic composition.

Authors:  James D Rijken; Christopher J Colyer
Journal:  J Appl Clin Med Phys       Date:  2017-08-30       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.