Literature DB >> 21059047

Quantification of equine sacral and iliac motion during gait: a comparison between motion capture with skin-mounted and bone-fixated sensors.

L Goff1, P R Van Weeren, L Jeffcott, P Condie, C McGowan.   

Abstract

REASONS FOR PERFORMING STUDY: Information regarding movement at the ilium and sacrum in nonlame horses during normal gait may assist in understanding the biomechanics of the equine sacroiliac joint.
OBJECTIVES: To determine the amount and direction of motion at the ilium and sacrum using 3D orientation sensors during walk and trot in sound Thoroughbreds. To compare results from sensors fixed to the skin with results from sensors fixed to bone-implanted pins.
METHODS: Three 3D wireless orientation sensors were mounted to the skin over the tuber sacrale (TS) and sacrum of 6 horses and motion at the ilium and sacrum was recorded for lateral bending (LB) flexion-extension (F-E) and axial rotation (AR) during walk and trot. This process was repeated with the orientation sensors mounted to the same pelvic landmarks via Steinmann pins.
RESULTS: Mean walk values were greater than trot values using pin-mounted sensors for all planes of movement (P < 0.05). Walk had 1.64 ± 0.22° (mean ± s.e.) more LB than trot (pin-mounted) yet 0.68 ± 0.22° less than trot when skin-mounted; 3.45 ± 0.15° more F-E (pin- and skin-mounted), and 4.99 ± 0.4° more AR (pin-mounted), but trot had 3.4 ± 0.40° more AR than walk with skin mounting. Using pinned sensors for trot resulted in less LB (2.47 ± 0.22°), F-E (1.12 ± 0.15°) and AR (10.62 ± 0.40°); and for walk less F-E (1.12 ± 0.15°) and AR (2.15 ± 0.40°) compared to skin-mounted. Poor correlation existed between mean values for skin- and pin-mounted data for walk and trot, for all planes of motion.
CONCLUSIONS: Movements were smaller at trot with bone-fixated sensors compared to walk, suggesting increased muscular control of movement at the trot. The apparent increase in skin motion at the trot and no clear correlation between skin- and bone-mounted sensors indicates inaccuracies when measuring sacral and iliac movement with skin mounting.
© 2010 EVJ Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 21059047     DOI: 10.1111/j.2042-3306.2010.00204.x

Source DB:  PubMed          Journal:  Equine Vet J Suppl


  3 in total

1.  Quantification of the effect of instrumentation error in objective gait assessment in the horse on hindlimb symmetry parameters.

Authors:  F M Serra Bragança; M Rhodin; T Wiestner; E Hernlund; T Pfau; P R van Weeren; M A Weishaupt
Journal:  Equine Vet J       Date:  2017-11-01       Impact factor: 2.888

2.  Differential rotational movement and symmetry values of the thoracolumbosacral region in high-level dressage horses when trotting.

Authors:  Russell MacKechnie-Guire; Thilo Pfau
Journal:  PLoS One       Date:  2021-05-06       Impact factor: 3.240

3.  Differential Rotational Movement of the Thoracolumbosacral Spine in High-Level Dressage Horses Ridden in a Straight Line, in Sitting Trot and Seated Canter Compared to In-Hand Trot.

Authors:  Russell MacKechnie-Guire; Thilo Pfau
Journal:  Animals (Basel)       Date:  2021-03-20       Impact factor: 2.752

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.