Literature DB >> 21056679

Test-retest reliability of 3D kinematic gait variables in hip osteoarthritis patients.

D Laroche1, A Duval, C Morisset, J-N Beis, P d'Athis, J-F Maillefert, P Ornetti.   

Abstract

OBJECTIVES: (1) to investigate the test-retest reliability of 3D gait analysis (3DGA) in hip Osteoarthritis (OA) patients; (2) to find the minimum number of gait trials needed to overcome intrinsic variability; (3) to check the accuracy of angles measured by the 3D system.
DESIGN: 23 Patients suffering from hip OA with no other major disease were recruited. We evaluated the reliability of spatio-temporal variables and body angles (lower-limb joints, trunk and pelvis angles) during two sessions of 3DGA using intra-class correlation coefficients (ICC). The minimum number of trials needed to overcome intrinsic variability was evaluated using an exponential fit model and the Bland and Altman coefficient of repeatability (CoR). The accuracy of measurement was evaluated using a manual goniometer and the recording of 18 different angles.
RESULTS: Spatio-temporal variables and most of the kinematic joint and trunk angles calculated demonstrated good to excellent reliability (ICC from 0.77 to 0.97). This was not the case for pelvic angles. The fitting model combined with the CoR showed that 5-10 trials are sufficient to obtain good reliability [ICC>0.7; CoR<2 standard deviation (SD)] for most of the spatio-temporal variables. All body angles showed good reliability (ICC>0.7) and low CoR (<2 SD) after five trials except for the pelvic angles. The reliability of marker positioning was found to be good (ICC>0.7) to excellent (ICC>0.9). Differences between angles measured using 3DGA and angles measured with a manual goniometer were found to be less than one percent.
CONCLUSION: The present study shows that most of variables obtained using 3DGA in hip OA patients are reliable. Moreover, for most variables, 5-10 trials are needed to obtain good reliability and to overcome intrinsic variability, rather than 30 or more, thus improving the feasibility of measurement.
Copyright © 2010 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21056679     DOI: 10.1016/j.joca.2010.10.024

Source DB:  PubMed          Journal:  Osteoarthritis Cartilage        ISSN: 1063-4584            Impact factor:   6.576


  13 in total

1.  Gait analysis dataset of healthy volunteers and patients before and 6 months after total hip arthroplasty.

Authors:  Aurélie Bertaux; Mathieu Gueugnon; Florent Moissenet; Baptiste Orliac; Pierre Martz; Jean-Francis Maillefert; Paul Ornetti; Davy Laroche
Journal:  Sci Data       Date:  2022-07-12       Impact factor: 8.501

2.  Test-Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects.

Authors:  Francisco Molina-Rueda; Pilar Fernández-González; Alicia Cuesta-Gómez; Aikaterini Koutsou; María Carratalá-Tejada; Juan Carlos Miangolarra-Page
Journal:  Int J Environ Res Public Health       Date:  2021-02-02       Impact factor: 3.390

3.  No effects of a 12-week supervised exercise therapy program on gait in patients with mild to moderate osteoarthritis: a secondary analysis of a randomized trial.

Authors:  Ingrid Eitzen; Linda Fernandes; Lars Nordsletten; May Arna Risberg
Journal:  J Negat Results Biomed       Date:  2015-03-05

4.  Kinetic and kinematic follow-up gait analysis in Doberman Pinschers with cervical spondylomyelopathy treated medically and surgically.

Authors:  Kari D Foss; Rebecca L Smith; Ronaldo C da Costa
Journal:  J Vet Intern Med       Date:  2018-03-23       Impact factor: 3.333

5.  Different reliability of instrumented gait analysis between patients with unilateral hip osteoarthritis, unilateral hip prosthesis and healthy controls.

Authors:  Roland Zügner; Roy Tranberg; Vera Lisovskaja; Johan Kärrholm
Journal:  BMC Musculoskelet Disord       Date:  2018-07-18       Impact factor: 2.362

6.  Reliability of three-dimensional kinematic gait data in adults with spinal cord injury.

Authors:  Pia Wedege; Kathrin Steffen; Vegard Strøm; Arve Isak Opheim
Journal:  J Rehabil Assist Technol Eng       Date:  2017-09-14

7.  Sagittal plane gait characteristics in hip osteoarthritis patients with mild to moderate symptoms compared to healthy controls: a cross-sectional study.

Authors:  Ingrid Eitzen; Linda Fernandes; Lars Nordsletten; May Arna Risberg
Journal:  BMC Musculoskelet Disord       Date:  2012-12-20       Impact factor: 2.362

8.  Cross-talk correction method for knee kinematics in gait analysis using principal component analysis (PCA): a new proposal.

Authors:  Audrey Baudet; Claire Morisset; Philippe d'Athis; Jean-Francis Maillefert; Jean-Marie Casillas; Paul Ornetti; Davy Laroche
Journal:  PLoS One       Date:  2014-07-08       Impact factor: 3.240

9.  The Gait Deviation Index Is Associated with Hip Muscle Strength and Patient-Reported Outcome in Patients with Severe Hip Osteoarthritis-A Cross-Sectional Study.

Authors:  Signe Rosenlund; Anders Holsgaard-Larsen; Søren Overgaard; Carsten Jensen
Journal:  PLoS One       Date:  2016-04-11       Impact factor: 3.240

10.  A Wearable Magneto-Inertial System for Gait Analysis (H-Gait): Validation on Normal Weight and Overweight/Obese Young Healthy Adults.

Authors:  Valentina Agostini; Laura Gastaldi; Valeria Rosso; Marco Knaflitz; Shigeru Tadano
Journal:  Sensors (Basel)       Date:  2017-10-21       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.