Literature DB >> 21052321

Computed-tomography imaging spectrometer: experimental calibration and reconstruction results.

M Descour, E Dereniak.   

Abstract

A temporally and spatially nonscanning imaging spectrometer is described in terms of computedtomography concepts, specifically the central-slice theorem. A sequence of three transmission sinusoidalphase gratings rotated in 60° increments achieves dispersion in multiple directions and into multiple orders. The dispersed images of the system's field stop are interpreted as two-dimensional projections of a three-dimensional (x, y, λ) object cube. Because of the size of the finite focal-plane array, this imaging spectrometer is an example of a limited-view-angle tomographic system. The imaging spectrometer's point spread function is measured experimentally as a function of wavelength and position in the field of view. Reconstruction of the object cube is then achieved through the maximum-likelihood, expectation-maximization algorithm under the assumption of a Poisson likelihood law. Experimental results indicate that the instrument performs well in the case of broadband and narrow-band emitters.

Year:  1995        PMID: 21052321     DOI: 10.1364/AO.34.004817

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  16 in total

1.  Image mapping spectrometry: calibration and characterization.

Authors:  Noah Bedard; Nathan Hagen; Liang Gao; Tomasz S Tkaczyk
Journal:  Opt Eng       Date:  2012-11-01

Review 2.  Optical hyperspectral imaging in microscopy and spectroscopy - a review of data acquisition.

Authors:  Liang Gao; R Theodore Smith
Journal:  J Biophotonics       Date:  2014-09-03       Impact factor: 3.207

3.  Snapshot hyperspectral light field tomography.

Authors:  Qi Cui; Jongchan Park; Yayao Ma; Liang Gao
Journal:  Optica       Date:  2021-12-08       Impact factor: 10.644

4.  A review of snapshot multidimensional optical imaging: measuring photon tags in parallel.

Authors:  Liang Gao; Lihong V Wang
Journal:  Phys Rep       Date:  2016-02-29       Impact factor: 25.600

5.  Noninvasive assessment of retinal vascular oxygen content among normal and diabetic human subjects: a study using hyperspectral computed tomographic imaging spectroscopy.

Authors:  Amir H Kashani; Gilberto R Lopez Jaime; Saloomeh Saati; Gabriel Martin; Rohit Varma; Mark S Humayun
Journal:  Retina       Date:  2014-09       Impact factor: 4.256

6.  Snapshot advantage: a review of the light collection improvement for parallel high-dimensional measurement systems.

Authors:  Nathan Hagen; Robert T Kester; Liang Gao; Tomasz S Tkaczyk
Journal:  Opt Eng       Date:  2012-06-13

7.  Nanohole-array-based device for 2D snapshot multispectral imaging.

Authors:  Mohamadreza Najiminaini; Fartash Vasefi; Bozena Kaminska; Jeffrey J L Carson
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

8.  Hyperspectral computed tomographic imaging spectroscopy of vascular oxygen gradients in the rabbit retina in vivo.

Authors:  Amir H Kashani; Erlinda Kirkman; Gabriel Martin; Mark S Humayun
Journal:  PLoS One       Date:  2011-09-13       Impact factor: 3.240

9.  Acute variations in retinal vascular oxygen content in a rabbit model of retinal venous occlusion.

Authors:  Gilberto Raul Lopez Jaime; Amir H Kashani; Saloomeh Saati; Gabriel Martin; Gerald Chader; Mark S Humayun
Journal:  PLoS One       Date:  2012-11-20       Impact factor: 3.240

Review 10.  Modern technologies for retinal scanning and imaging: an introduction for the biomedical engineer.

Authors:  Boris I Gramatikov
Journal:  Biomed Eng Online       Date:  2014-04-29       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.