Frequency, tidal volume, and mean airway pressure combinations that provide adequate gas exchange and low alveolar pressure during high frequency oscillatory ventilation in rabbits.

M D Kamitsuka1, B R Boynton, D Villanueva, P N Vreeland, I D Frantz.   

Abstract

We studied healthy and saline lavaged rabbits during high frequency oscillatory ventilation to determine what combination of frequency (f), tidal volume (Vt), and mean airway pressure (Paw) produced the lowest peak-to-peak alveolar pressure amplitude (Palv) and physiologic blood gas tensions. Sinusoidal volume changes were delivered through a tracheostomy by a piston pump driven by a linear motor. Tracheal pressure amplitude (Ptr) was measured through a tracheal catheter and alveolar pressure amplitude was measured in a capsule glued to the right lower lobe. PaO2, PaCO2, Ptr, and Palv were measured at the following settings: FiO2 = 0.5, frequency 2-28 Hz, Vt 1-3 mL/kg (50 150% dead space) and Paw 5-15 cm H2O. Many combinations of frequency and Vt resulted in the same PaO2 and PaCO2. Paw had a large effect on Palv and minimal effect on blood gas tensions. In lavaged rabbits, the composite variable f x Vt2 described the trends in Palv and blood gas tensions. As the product of f x Vt2 increased, PaO2 initially increased and then decreased, whereas PaCO2 decreased and Palv increased. No single combination of frequency, Vt and Paw simultaneously provided the lowest Palv and physiologic blood gas tensions. Adequate blood gas tensions and low Palv were obtained at frequencies less than 12 Hz, a Vt of 2 mL/kg and a Paw of 10 cm H2O. In healthy and lavaged rabbits PaO2 increased and PaCO2 decreased as frequency increased at lower Vt.PaO2 decreased as frequency increased at higher Vt in lavaged rabbits only. Palv tended to be greater in lavaged rabbits.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2104970     DOI: 10.1203/00006450-199001000-00018

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  7 in total

1.  Volume delivery during high frequency oscillation.

Authors:  G Dimitriou; A Greenough; V Kavvadia; B Laubscher; A D Milner
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1998-03       Impact factor: 5.747

Review 2.  High frequency oscillation.

Authors:  A Greenough
Journal:  Eur J Pediatr       Date:  1994       Impact factor: 3.183

3.  Total and regional lung volume changes during high-frequency oscillatory ventilation (HFOV) of the normal lung.

Authors:  R Blaine Easley; Christopher T Lancaster; Matthew K Fuld; Jason W Custer; David N Hager; David W Kaczka; Brett A Simon
Journal:  Respir Physiol Neurobiol       Date:  2008-10-18       Impact factor: 1.931

4.  High frequency oscillatory ventilation near resonant frequency of the respiratory system in rabbits with normal and surfactant depleted lungs.

Authors:  A Schulze; P Schaller; J Dinger; U Winkler; D Gmyrek
Journal:  Eur J Pediatr       Date:  1991-07       Impact factor: 3.183

5.  Measurement of lung volume and optimal oxygenation during high frequency oscillation.

Authors:  G Dimitriou; A Greenough
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-05       Impact factor: 5.747

6.  Ventilation-induced jet suggests biotrauma in reconstructed airways of the intubated neonate.

Authors:  Eliram Nof; Metar Heller-Algazi; Filippo Coletti; Dan Waisman; Josué Sznitman
Journal:  J R Soc Interface       Date:  2020-01-08       Impact factor: 4.118

7.  Hemodynamic effects of high frequency oscillatory ventilation with volume guarantee in a piglet model of respiratory distress syndrome.

Authors:  Jagmeet Bhogal; Anne Lee Solevåg; Megan O'Reilly; Tze-Fun Lee; Chloe Joynt; Lisa K Hornberger; Georg M Schmölzer; Po-Yin Cheung
Journal:  PLoS One       Date:  2021-02-16       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.