Literature DB >> 21041132

Thresholds for nonlinear effects in high- intensity focused ultrasound propagation and tissue heating.

Joshua E Soneson1, Matthew R Myers.   

Abstract

For a variety of reasons, including their simplicity and ability to capitalize upon superposition, linear acoustic propagation models are preferable to nonlinear ones in modeling the propagation of high-intensity focused ultrasound (HIFU) beams. However, under certain conditions, nonlinear models are necessary to accurately model the beam propagation and heating. In analyzing the performance of a HIFU system, it is advantageous to know before the analysis whether a linear model suffices. This paper examines the problem of determining the thresholds at which nonlinear effects become important. It is demonstrated that nonlinear interaction has different effects on different physical and derived quantities, such as compressional pressure, rarefactional pressure, intensity, heat rate, temperature rise, and thermal lesion volume. Thresholds are determined as a function of the dimensionless gain, nonlinearity, and absorption parameters. The relative difference between linear and nonlinear predictions is plotted as a series of contours, enabling practitioners to locate their system in parameter space and determine whether nonlinearity significantly affects the quantities of interest.

Mesh:

Year:  2010        PMID: 21041132     DOI: 10.1109/TUFFC.2010.1711

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study.

Authors:  Marjan Nabili; Craig Geist; Vesna Zderic
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

Review 2.  Conditionally Increased Acoustic Pressures in Nonfetal Diagnostic Ultrasound Examinations Without Contrast Agents: A Preliminary Assessment.

Authors:  Kathryn R Nightingale; Charles C Church; Gerald Harris; Keith A Wear; Michael R Bailey; Paul L Carson; Hui Jiang; Kurt L Sandstrom; Thomas L Szabo; Marvin C Ziskin
Journal:  J Ultrasound Med       Date:  2015-07       Impact factor: 2.153

3.  Characterization of a multi-element clinical HIFU system using acoustic holography and nonlinear modeling.

Authors:  Wayne Kreider; Petr V Yuldashev; Oleg A Sapozhnikov; Navid Farr; Ari Partanen; Michael R Bailey; Vera A Khokhlova
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-08       Impact factor: 2.725

4.  Spherical Array System for High-Precision Transcranial Ultrasound Stimulation and Optoacoustic Imaging in Rodents.

Authors:  Hector Estrada; Ali Ozbek; Justine Robin; Shy Shoham; Daniel Razansky
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-12-23       Impact factor: 2.725

5.  Quantifying cell death induced by doxorubicin, hyperthermia or HIFU ablation with flow cytometry.

Authors:  Paul Christopher Lyon; Visa Suomi; Philip Jakeman; Leticia Campo; Constantin Coussios; Robert Carlisle
Journal:  Sci Rep       Date:  2021-02-23       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.