Literature DB >> 21035810

Development of a solid-phase extraction with capillary liquid chromatography tandem mass spectrometry for analysis of estrogens in environmental water samples.

Petr Kozlík1, Zuzana Bosáková, Eva Tesařová, Pavel Coufal, Radomír Cabala.   

Abstract

Capillary liquid chromatography (cLC) hyphenated with tandem mass spectrometry (MS-MS) was used to separate and quantitate trace concentrations of five estrogens in aqueous samples. New C(18)-based sorption materials bound to the silica support by monomeric and polymeric mechanisms were compared and tested for solid-phase extraction (SPE) of selected analytes with respect to optimization of their preconcentration yield. Application of an endcapped, monomer-bound preconcentration Discovery DSC-18Lt column under the optimized conditions provides yields in the range from 95 to 100% with a high repeatability (n=3, RSD≤7.2%). Using the electrospray ionization in the positive mode (ESI+), the cLC-MS-MS system (the Zorbax SB C18 capillary column and a binary mobile phase of acetonitrile and water containing 0.1% formic acid in both the components) was optimized to attain a sufficient retention of the early eluting estriol, a satisfactory resolution of the analytes and the maximum sensitivity of the determination. Both the isocratic and gradient elution were used and the optimized gradient method permitted analyses of aqueous environmental samples in 14 min within a linearity range from 6.1 to 25.0 (LOQ of analytes) to 500 ng/L and with a very good linearity (r>0.9981) for all the estrogens studied. The detection limits are in the range from 3.0 to 6.8 ng/L (1 μL injection volume). Six environmental water samples were analyzed and the studied estrogens were found in the Vltava river sample collected in Prague (13.2 ng/L for 17β-estradiol) and in the inlet to the wastewater treatment plant in Prague, at an overall concentration of 371.4 ng/L.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21035810     DOI: 10.1016/j.chroma.2010.10.033

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Integrated standardization concept for Angelica botanicals using quantitative NMR.

Authors:  Tanja Gödecke; Ping Yao; José G Napolitano; Dejan Nikolić; Birgit M Dietz; Judy L Bolton; Richard B van Breemen; Norman R Farnsworth; Shao-Nong Chen; David C Lankin; Guido F Pauli
Journal:  Fitoterapia       Date:  2011-09-01       Impact factor: 2.882

2.  Kinetic Study of 17α-Estradiol Mechanism during Rat Sperm Capacitation.

Authors:  Tereza Bosakova; Antonin Tockstein; Zuzana Bosakova; Katerina Komrskova
Journal:  Molecules       Date:  2022-06-25       Impact factor: 4.927

Review 3.  Reproductive drugs and environmental contamination: quantum, impact assessment and control strategies.

Authors:  Harpreet Kaur; Madhu Bala; Gulshan Bansal
Journal:  Environ Sci Pollut Res Int       Date:  2018-07-23       Impact factor: 4.223

4.  A nanocomposite consisting of graphene oxide, zeolite imidazolate framework 8, and a molecularly imprinted polymer for (multiple) fiber solid phase microextraction of sterol and steroid hormones prior to their quantitation by HPLC.

Authors:  Roya Mirzajani; Fatemeh Kardani; Zahra Ramezani
Journal:  Mikrochim Acta       Date:  2019-02-01       Impact factor: 5.833

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.