Literature DB >> 21035645

Simultaneous electrochemical determination of nitrate and nitrite in aqueous solution using Ag-doped zeolite-expanded graphite-epoxy electrode.

Florica Manea1, Adriana Remes, Ciprian Radovan, Rodica Pode, Stephen Picken, Joop Schoonman.   

Abstract

In this work a new electrochemical sensor based on an Ag-doped zeolite-expanded graphite-epoxy composite electrode (AgZEGE) was evaluated as a novel alternative for the simultaneous quantitative determination of nitrate and nitrite in aqueous solutions. Cyclic voltammetry was used to characterize the electrochemical behavior of the electrode in the presence of individual or mixtures of nitrate and nitrite anions in 0.1M Na(2)SO(4) supporting electrolyte. Linear dependences of current versus nitrate and nitrite concentrations were obtained for the concentration ranges of 1-10mM for nitrate and 0.1-1mM for nitrite using cyclic voltammetry (CV), chronoamperometry (CA), and multiple-pulsed amperometry (MPA) procedures. The comparative assessment of the electrochemical behavior of the individual anions and mixtures of anions on this modified electrode allowed determining the working conditions for the simultaneous detection of the nitrite and nitrate anions. Applying MPA allowed enhancement of the sensitivity for direct and indirect nitrate detection and also for nitrite detection. The proposed sensor was applied in tap water samples spiked with known nitrate and nitrite concentrations and the results were in agreement with those obtained by a comparative spectrophotometric method. This work demonstrates that using multiple-pulse amperometry with the Ag-doped zeolite-expanded graphite-epoxy composite electrode provides a real opportunity for the simultaneous detection of nitrite and nitrate in aqueous solutions.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21035645     DOI: 10.1016/j.talanta.2010.08.042

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode.

Authors:  Anamaria Baciu; Magdalena Ardelean; Aniela Pop; Rodica Pode; Florica Manea
Journal:  Sensors (Basel)       Date:  2015-06-19       Impact factor: 3.576

2.  Using Diazotization Reaction to Develop Portable Liquid-Crystal-Based Sensors for Nitrite Detection.

Authors:  Tsung Yang Ho; Yi-Hsuan Lan; Jhih-Wei Huang; Jung-Jung Chang; Chih-Hsin Chen
Journal:  ACS Omega       Date:  2020-05-08

Review 3.  Removal of the Harmful Nitrate Anions from Potable Water Using Different Methods and Materials, including Zero-Valent Iron.

Authors:  Hany M Abd El-Lateef; Mai M Khalaf; Alaa El-Dien Al-Fengary; Mahmoud Elrouby
Journal:  Molecules       Date:  2022-04-14       Impact factor: 4.927

4.  Developing a novel paper-based enzymatic biosensor assisted by digital image processing and first-order multivariate calibration for rapid determination of nitrate in food samples.

Authors:  Ali R Jalalvand; Majid Mahmoudi; Hector C Goicoechea
Journal:  RSC Adv       Date:  2018-06-27       Impact factor: 3.361

5.  Strategic Electrochemical Determination of Nitrate over Polyaniline/Multi-Walled Carbon Nanotubes-Gum Arabic Architecture.

Authors:  Samia Abdulhammed Mohamad Kosa; Amna Nisar Khan; Sana Ahmed; Mohammad Aslam; Wafa AbuBaker Bawazir; Abdul Hameed; Muhammad Tahir Soomro
Journal:  Nanomaterials (Basel)       Date:  2022-10-10       Impact factor: 5.719

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.