Periprocedural safety of 64-detector row coronary computed tomographic angiography: results from the prospective multicenter ACCURACY trial.

George W Bell1, Michael Edwardes, Allison M Dunning, Sidney Glasofer, Fay Y Lin, Troy M Labounty, Augustin Delago, Matthew J Budoff, James K Min.   

Abstract

BACKGROUND: Coronary computed tomographic angiography (CCTA) requires iodinated contrast and often atrioventricular nodal blocking agents and nitroglycerin for heart rate lowering and coronary vasodilation, respectively. To date, the periprocedural safety of CCTA is unknown.
OBJECTIVES: The purpose of this study was to evaluate the periprocedural safety of CCTA.
METHODS: We prospectively evaluated 232 patients with symptomatic chest pain without preexisting renal insufficiency at 16 sites who underwent CCTA as part of the Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography (ACCURACY) trial. Patients received iodinated contrast, β-blockers, and nitroglycerin as part of a predefined CCTA protocol. We assessed the rates of adverse events (AEs) related to these agents.
RESULTS: As measured by serum creatinine and creatinine clearance, no significant change was observed in renal function from baseline (1.00 ± 0.19 mg/dL; modification of diet in renal disease [MDRD]: 76.91 ± 17.96 mL/min/1.73 m(2)) to 48 hours (1.0 ± 0.2 mg/dL; P = 1.00; MDRD change: 0.2 ± 12.4 mL/min/1.73 m(2); P = 0.83) or at 30 days (1.0 ± 0.2 mg/dL; P = 0.52; MDRD change: -0.9 ± 16.9 mL/min/1.73 m(2); P = 0.77). Mean systolic blood pressure decreased from baseline (133 ± 19 mm Hg) at 1 hour (125 ± 17 mm Hg; P < 0.001) and rebounded at 48 hours (133 ± 17 mm Hg). Mean heart rate decreased from baseline (65 ± 10 beats/min) at 1 hour (60 ± 7 beats/min) but rose at 48 hours (69 ± 11 beats/min; P < 0.001. All patients were asymptomatic from baseline to follow-up.
CONCLUSIONS: The performance of CCTA is safe with low rates of AEs.
© 2010 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21030334     DOI: 10.1016/j.jcct.2010.08.003

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  4 in total

1.  Identification of noncalcified plaque in young persons with diabetes: an opportunity for early primary prevention of coronary artery disease identified with low-dose coronary computed tomographic angiography.

Authors:  Paul M Madaj; Matthew J Budoff; Dong Li; John A Tayek; Ronald P Karlsberg; Harold L Karpman
Journal:  Acad Radiol       Date:  2012-04-26       Impact factor: 3.173

2.  Costs and clinical outcomes for non-invasive versus invasive diagnostic approaches to patients with suspected in-stent restenosis.

Authors:  James K Min; James T Hasegawa; Susanne F Machacz; Ken O'Day
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-03       Impact factor: 2.357

3.  Coronary artery disease in patients with atypical chest pain with and without diabetes mellitus assessed with coronary CT angiography.

Authors:  Marije M G Krul; Kjell Bogaard; Remco J J Knol; Albert C van Rossum; Paul Knaapen; Jan H Cornel; Friso M van der Zant
Journal:  BMJ Open Diabetes Res Care       Date:  2014-04-23

4.  Factors influencing the safety of outpatient coronary CT angiography: a clinical registry study.

Authors:  Florian Andre; Philipp Fortner; Mostafa Emami; Sebastian Seitz; Matthias Brado; Friedemann Gückel; Roman Sokiranski; André Sommer; Norbert Frey; Johannes Görich; Sebastian J Buss
Journal:  BMJ Open       Date:  2022-08-08       Impact factor: 3.006