Literature DB >> 21029335

In vivo temperature measurement: tooth preparation and restoration with preheated resin composite.

Frederick A Rueggeberg1, Márcia Daronch, William D Browning, Mario F DE Goes.   

Abstract

STATEMENT OF THE PROBLEM: Composite preheating has shown to improve material physical properties in vitro, but no data exist on the use of this technique in vivo during placement.
PURPOSE: The study aims to measure in vivo prepared tooth surface temperature during a restorative procedure using resin composite either at room temperature (23.6°C) or preheated to 54.7°C in a commercial compule heating device set to heat at 60°C.
METHODS: Class I preparations (N=3) were made on a patient requiring multiple posterior restorations. A probe containing two thermocouples was used to record temperature values at the tooth pulpal floor and 2mm higher (top of the tooth preparation/restoration) after tooth preparation (prep), acid etching (etch), placement and curing of a bonding agent (BA), and during placement of composite used at room temperature (RT) or preheated in a commercial device (Calset(TM) , AdDent Inc., Danbury, CT, USA) set to 60°C. Data were compared with two-way analysis of variance, Tukey-Kramer post hoc test (α=0.05).
RESULTS: No significant difference in pulpal floor temperature existed between prep (27.8°±1.3°C) and etch (26.3°±1.3°C), which were significantly lower than BA (30.5°±1.3°C) (p=0.0001). Immediate placement of preheated composite resulted in significantly higher pulpal floor (36.2°±1.9°C) (p=0.0025) and top composite temperatures (38.4°±2.2°C) (p=0.0034) than RT values (30.4°±2.2°C and 29.6°±0.9°C, respectively).
CONCLUSIONS: In vivo use and placement of preheated resin composite resulted in temperature increase of 6° to 8°C than room temperature material. These values, however, were much lower than expected. CLINICAL SIGNIFICANCE: Although having many potential benefits, composite preheating may not be as clinically effective in delivering resin of predetermined temperature at the time of cure as laboratory experiments would suggest. Despite only moderate composite temperature increase over use of room temperature material, preheating still provides advantages in terms of ease of handling and placement.
© 2010, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2010, WILEY PERIODICALS, INC.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21029335     DOI: 10.1111/j.1708-8240.2010.00358.x

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  7 in total

1.  Marginal adaptation of ceramic and composite inlays in minimally invasive mod cavities.

Authors:  M Zaruba; R Kasper; R Kazama; F J Wegehaupt; A Ender; T Attin; A Mehl
Journal:  Clin Oral Investig       Date:  2013-05-01       Impact factor: 3.573

2.  A Comparison of Microtensile Bond Strength, Film Thickness, and Microhardness of Photo-Polymerized Luting Composites.

Authors:  Farid El-Askary; Abdullah Hassanein; Emad Aboalazm; Nadin Al-Haj Husain; Mutlu Özcan
Journal:  Materials (Basel)       Date:  2022-04-22       Impact factor: 3.748

3.  Flexural Strength of Preheated Resin Composites and Bonding Properties to Glass-Ceramic and Dentin.

Authors:  Matthias Richard Kramer; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-01-29       Impact factor: 3.623

Review 4.  Composite Pre-heating: A Novel Approach in Restorative Dentistry.

Authors:  Jay Bhopatkar; Anuja Ikhar; Manoj Chandak; Nikhil Mankar; Shweta Sedani
Journal:  Cureus       Date:  2022-07-22

5.  Effect of preheating of low shrinking resin composite on intrapulpal temperature and microtensile bond strength to dentin.

Authors:  Heba A El-Deeb; Sara Abd El-Aziz; Enas H Mobarak
Journal:  J Adv Res       Date:  2014-12-24       Impact factor: 10.479

6.  Influence of preheating the bonding agent of a conventional three-step adhesive system and the light activated resin cement on dentin bond strength.

Authors:  Daniel Brandão Vilela Holanda; Fabiana Mantovani Gomes França; Flávia Lucisano Botelho do Amaral; Flávia Martão Flório; Roberta Tarkany Basting
Journal:  J Conserv Dent       Date:  2013-11

7.  Pre-heating mitigates composite degradation.

Authors:  Jessika Calixto da Silva; Reges Rogério Vieira; Inara Carneiro Costa Rege; Carlos Alberto dos Santos Cruz; Luís Geraldo Vaz; Carlos Estrela; Fabrício Luscino Alves de Castro
Journal:  J Appl Oral Sci       Date:  2015 Nov-Dec       Impact factor: 2.698

  7 in total