Literature DB >> 21028950

Biomechanical finite element analysis of small diameter and short dental implant.

Istabrak Hasan1, Friedhelm Heinemann, Maria Aitlahrach, Christoph Bourauel.   

Abstract

Abstract Short and mini dental implants have been widely used as treatment alternatives in certain selected clinical situations. However, a profound scientific analysis of the mechanical and biomechanical impact of the reduced length and diameter of these implant geometries has not been published until now. Using finite element analysis, a series of different experimentally designed short and mini implants have been analysed with regard to their load transfer to the alveolar bone and have been compared to respective standard commercial implants. Mini implants have been inserted in an idealised bone bed representing the anterior mandibular jaw region and loaded with a force of 150 N. An immediate loading condition was assumed and analysed using the contact analysis option of the FE package MSC.Marc/Mentat. Short implants were inserted in an idealised posterior bone segment and loaded in osseointegrated state with forces of 300 N. Clearly increased bone loading was observed for the short and mini dental implants compared with standard implants, clearly exceeding the physiological limit of 100 MPa. The determined biomechanical characteristics could explain the slightly increased failure rate of short and mini dental implants.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21028950     DOI: 10.1515/BMT.2010.049

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  7 in total

1.  Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

Authors:  W Aunmeungtong; P Khongkhunthian; P Rungsiyakull
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

2.  Biomechanical evaluations of the long-term stability of dental implant using finite element modeling method: a systematic review.

Authors:  Seyed Aref Hosseini-Faradonbeh; Hamid Reza Katoozian
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

3.  Finite element analysis of stress distribution around short and long implants in mandibular overdenture treatment.

Authors:  Yeghaneh Memari; Parisa Fattahi; Amir Fattahi; Solmaz Eskandarion; Vahid Rakhshan
Journal:  Dent Res J (Isfahan)       Date:  2020-01-21

4.  Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible.

Authors:  Lana Zupancic Cepic; Martin Frank; Andreas Reisinger; Dieter Pahr; Werner Zechner; Andreas Schedle
Journal:  Int J Implant Dent       Date:  2022-02-11

5.  Biomechanics and load resistance of short dental implants: a review of the literature.

Authors:  Istabrak Hasan; Christoph Bourauel; Torsten Mundt; Friedhelm Heinemann
Journal:  ISRN Dent       Date:  2013-05-08

6.  Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading.

Authors:  Raif Alan; İsmail Marakoğlu; Seyfullah Haliloğlu
Journal:  J Periodontal Implant Sci       Date:  2015-10-26       Impact factor: 2.614

7.  Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis.

Authors:  Cleidiel Aparecido Araujo Lemos; Fellippo Ramos Verri; Joel Ferreira Santiago Junior; Victor Eduardo de Souza Batista; Daniel Takanori Kemmoku; Pedro Yoshito Noritomi; Eduardo Piza Pellizzer
Journal:  J Healthc Eng       Date:  2018-09-03       Impact factor: 2.682

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.