| Literature DB >> 2098559 |
D E Clark1, R A Danforth, R W Barnes, M L Burtch.
Abstract
Absorbed radiation dose in bone marrow, thyroid, salivary gland, eye, and skin entrance was determined by placement of lithium fluoride thermoluminescent dosimeters (TLD's) at selected anatomical sites within and on a human-like x-ray phantom. The phantom was exposed to radiation from linear tomographic and computer-assisted tomographic (CT) simulated dental implant radiographic examinations. The mean dose was determined for each anatomical site. Resulting dose measurements from linear tomography and computer-assisted tomography are compared with reported panoramic and intra-oral doses. CT examination delivered the greatest dose, while linear tomography was generally lowest. Panoramic and intra-oral doses were similar to those of linear tomography.Entities:
Mesh:
Year: 1990 PMID: 2098559
Source DB: PubMed Journal: J Oral Implantol ISSN: 0160-6972 Impact factor: 1.779