Comparison of two control measures of weatherstripping in reducing blowing dust during hospital renovations.

Koji Yahara1, Miho Miura, Kenji Masunaga, Kazuhiro Matsumoto, Toshiyuki Miyao, Chiyoko Tanamachi, Koji Hashimoto, Kimitaka Sagawa, Hiroshi Watanabe.   

Abstract

Hospital renovation projects pose risks of invasive infection by fungi from dust that is blown about during the period in question. Control measures to reduce the amount of dust during hospital renovation are thus necessary. Currently, no study has compared different control measures for effectiveness through more than one period of renovation. In this study, we examined the capacities of two control measures of weatherstripping (0.15 mm poly film and adhesive tape) to reduce the amount of blowing dust during two different hospital renovations (in 2008 and 2009). The amount of dust in the air of the hospital before and during the renovation was measured about once a week in both 2008 and 2009, and the between-year and within-year differences were tested. Our study revealed that the weatherstripping used in 2009 (adhesive tape) was significantly more effective than the measures taken in 2008 (0.15 mm poly film) to reduce the amount of dust during the renovations (p < 0.001), while in both years the amount of dust became significantly higher during the renovations than before the renovations. Differences in the effectiveness of weatherstripping during renovations between floors of the hospital were not significant in both 2008 and 2009. The number of Aspergillus-positive samples did not significantly increase compared with the number observed before the start of the hospital renovations (2006-2007) in 2008 and 2009, respectively. The weatherstripping potentially reduced the associated risk of airborne fungal infection.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20981562     DOI: 10.1007/s10156-010-0173-2

Source DB:  PubMed          Journal:  J Infect Chemother        ISSN: 1341-321X            Impact factor:   2.211


  2 in total

1.  Effect of sticky mat usage in control of nosocomial infection in Motahary Burn Hospital.

Authors:  Mostafa Dahmardehei; Faranak Alinejad; Fereshteh Ansari; Mahnaz Bahramian; Mitra Barati
Journal:  Iran J Microbiol       Date:  2016-06

2.  Profiles of Environmental Mold: Indoor and Outdoor Air Sampling in a Hematology Hospital in Seoul, South Korea.

Authors:  Sung-Yeon Cho; Jun-Pyo Myong; Won-Bok Kim; Chulmin Park; Sung Jeon Lee; Sang Hyeon Lee; Dong-Gun Lee
Journal:  Int J Environ Res Public Health       Date:  2018-11-15       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.