| Literature DB >> 20979410 |
Alexander Kleefen1, Daniel Pedone, Christian Grunwald, Ruoshan Wei, Matthias Firnkes, Gerhard Abstreiter, Ulrich Rant, Robert Tampé.
Abstract
We introduce a nanofabricated silicon chip for massively multiplexed analysis of membrane channels and transporters in suspended lipid membranes that does not require any surface modification or organic solvent. Transport processes through single membrane complexes are monitored by fluorescence. The chip consists of an array of well-defined nanopores, addressing an individual pyramidal back-reflecting 30-fL compartment. The setup allows simultaneous analyses of ∼1,000 single transmembrane events in one field of view, observing translocation kinetics of transmembrane complexes.Entities:
Year: 2010 PMID: 20979410 DOI: 10.1021/nl1033528
Source DB: PubMed Journal: Nano Lett ISSN: 1530-6984 Impact factor: 11.189