Literature DB >> 20978996

Quality assurance and quality control of thrombelastography and rotational Thromboelastometry: the UK NEQAS for blood coagulation experience.

Dianne P Kitchen1, Steve Kitchen, Ian Jennings, Tim Woods, Isobel Walker.   

Abstract

Global hemostasis devices are currently being employed in operating rooms to assess the bleeding risk and outcomes for patients undergoing surgery. Two devices currently available are the TEG (Thromboelastograph; Haemoscope Corp., Niles, IL) and the ROTEM (Rotation Thromboelastometer; Pentapharm GmbH, Munich, Germany). Both measure the speed of clot formation, the strength of the clot when formed, and clot fibrinolysis kinetics. The two devices use different parameters so no cross comparisons of results can be made. The devices are usually operated by a member of the operating team and not a laboratory scientist; thus their testing and performance is generally not laboratory controlled, despite quality control being required to ensure reliable results. The UK National External Quality Assessment Scheme (NEQAS) for Blood Coagulation has undertaken a series of exercises evaluating the provision of External Quality Assessment (EQA) material for these devices. A series of four studies have taken place using lyophilized plasmas as the test material. Up to 18 TEG users and 10 ROTEM users have been involved in testing two samples per study, for a total of eight samples tested. The samples were normal plasmas, factor VIII or XI deficient samples, or normal plasmas spiked with heparin. The precision of the tests varied greatly for both devices, with coefficients of variances ranging from 7.1 to 39.9% for TEG and 7.0 to 83.6% for ROTEM. Some centers returned results that were sufficiently different from those obtained by other participants to predict alterations in patient management decisions. Our data indicate that regular EQA/proficiency testing is needed for these devices. © Thieme Medical Publishers.

Entities:  

Mesh:

Year:  2010        PMID: 20978996     DOI: 10.1055/s-0030-1265292

Source DB:  PubMed          Journal:  Semin Thromb Hemost        ISSN: 0094-6176            Impact factor:   4.180


  14 in total

Review 1.  What's new in the diagnostic criteria of disseminated intravascular coagulation?

Authors:  Satoshi Gando; Ferhat Meziani; Marcel Levi
Journal:  Intensive Care Med       Date:  2016-02-08       Impact factor: 17.440

2.  Reference values for kaolin-activated thromboelastography in volunteers of Anhui Province in China.

Authors:  Jun-Bo Sun; Mao-Hong Bian; Tao Zhong; Ying-Yu Lu; Bang-Qiang Zhu; Hui-Qin Wen; Hai-Liang Hu
Journal:  J Clin Lab Anal       Date:  2017-01-30       Impact factor: 2.352

Review 3.  Bleeding Risk with Invasive Procedures in Patients with Cirrhosis and Coagulopathy.

Authors:  Nekisa Zakeri; Emmanuel A Tsochatzis
Journal:  Curr Gastroenterol Rep       Date:  2017-09

4.  [Early viscoelasticity-based coagulation therapy for severely injured bleeding patients: Report of the consensus group on the consensus conference 2014 for formulation of S2k guidelines].

Authors:  M Maegele; K Inaba; S Rizoli; P Veigas; J Callum; R Davenport; M Fröhlich; J Hess
Journal:  Anaesthesist       Date:  2015-10       Impact factor: 1.041

Review 5.  Global coagulation assays in hypercoagulable states.

Authors:  Hui Yin Lim; Geoffrey Donnan; Harshal Nandurkar; Prahlad Ho
Journal:  J Thromb Thrombolysis       Date:  2022-01-08       Impact factor: 2.300

6.  The authors reply.

Authors:  Ithan D Peltan; Timothy R Watkins
Journal:  Crit Care Med       Date:  2016-02       Impact factor: 7.598

Review 7.  Trauma-induced coagulopathy.

Authors:  Ernest E Moore; Hunter B Moore; Lucy Z Kornblith; Matthew D Neal; Maureane Hoffman; Nicola J Mutch; Herbert Schöchl; Beverley J Hunt; Angela Sauaia
Journal:  Nat Rev Dis Primers       Date:  2021-04-29       Impact factor: 65.038

Review 8.  A general review of major global coagulation assays: thrombelastography, thrombin generation test and clot waveform analysis.

Authors:  Marcus D Lancé
Journal:  Thromb J       Date:  2015-01-12

9.  Is viscoelastic coagulation monitoring with ROTEM or TEG validated?

Authors:  Cristina Solomon; Lars M Asmis; Donat R Spahn
Journal:  Scand J Clin Lab Invest       Date:  2016-06-29       Impact factor: 1.713

10.  Validation of a modified thromboelastometry approach to detect changes in fibrinolytic activity.

Authors:  Gerhardus J A J M Kuiper; Marie-Claire F Kleinegris; René van Oerle; Henri M H Spronk; Marcus D Lancé; Hugo Ten Cate; Yvonne M C Henskens
Journal:  Thromb J       Date:  2016-01-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.