Directly fabricated inlay-retained glass- and polyethylene fiber-reinforced composite fixed dental prostheses in posterior single missing teeth: a short-term clinical observation.

Ayça Deniz Izgi1, Sebnem Eskimez, Ediz Kale, Yalçın Değer.   

Abstract

PURPOSE: To evaluate the clinical usefulness of directly fabricated glass and polyethylene resin-bonded fiberreinforced composite (FRC) inlay-retained fixed dental prostheses (FDPs) in posterior single missing teeth over a short period of time.
MATERIALS AND METHODS: Fourteen inlay-retained FRC FDPs with tub-shaped or box-shaped retainers were directly constructed in patients of both genders. A baseline examination was performed and the patients were examined regularly at 6-month intervals. The sulcus bleeding index, Silness-Löe plaque index, and probing depths of the abutments were checked regularly. Modified US Public Health Service (USPHS) parameters were used to compare the restorations at baseline and final examination. The Kaplan-Meier survival estimation method was performed to detect the overall survival rates and mean survival times of the restorations at the end of the follow-up.
RESULTS: The length of the clinical observation was between 16 and 40 months for the FDPs still functioning after the end of the follow-up. No partial or total debonding of the prostheses or fracture of the frameworks was detected. Four veneering composite fractures at the veneer layer/fiber framework interface occurred in the pontic elements of 2 glass FRC FDPs and 2 polyethylene FRC FDPs after 6 and 10 months, and 20 and 22 months, respectively. Periodontal evaluation revealed clinically acceptable results, as did the USPHS evaluation. The overall survival curves of Kaplan-Meier at the end of the follow-up illustrated a 71% survival rate for the both glass and polyethylene FRC FDPs with mean survival times of 27 and 35 months, respectively.
CONCLUSION: This study reported a mean period of service of 19 and 31 months for directly fabricated inlayretained glass and polyethylene FRC FDPs, respectively, with a 71% survival rate for the two framework constructions. Within the limitations of the study, these results can only be considered as preliminary. However, because of the lack of clinical data available for directly fabricated inlay-retained FRC FDPs, the results of this clinical observation may contribute to the still-evolving clinical knowledge of the FRC restorations.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20978649     DOI: 10.3290/j.jad.a19470

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  3 in total

1.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

2.  Retrospective study on the 7.5-year survival of resin-bonded dental prostheses in single missing second premolar cases.

Authors:  Ayça Deniz İzgi; Şebnem Eskimez; Ediz Kale
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar

3.  A New Technique for Direct Fabrication of Fiber-Reinforced Composite Bridge: A Long-Term Clinical Observation.

Authors:  Matías Ferrán Escobedo Martínez; Samuel Rodríguez López; Jairo Valdés Fontela; Sonsoles Olay García; Mario Mauvezín Quevedo
Journal:  Dent J (Basel)       Date:  2020-05-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.