Literature DB >> 20977104

Vertebroplasty--high viscosity cement versus low viscosity cement.

S Rapan1, S Jovanović, G Gulan, V Boschi, V Kolarević, T Dapić.   

Abstract

The patients with intensive pain caused by the vertebra body fracture were treated by application of low viscosity cement (LVC), (Vertebroplastic, DePuy) and high viscosity cement (HVC), (Confidence, DePuy,) into the body, by means of diascopy through unilateral transpendicular approach. Application of LVC was made in 75 patients, on 109 vertebrae, and HVC was applied in 12 patients on 14 vertebrae. Application of LVC was performed on 48 thoracic and 61 lumbar vertebrae and 5 thoracic and 9 lumbar vertebrae were stabilized with HVC. 43 patients were treated for malignancy and in 38 for osteoporosis. For LVC, preoperative VAS score was 8.32 and 2.23 (p < 0.00001) 24 hours after surgery, and it remained stable 3 month later. For HVC, preoperative VAS score was 7.99 and it was 2.5 (p < 0.00001) 24 hours after surgery and 3 months later. In the group of patients treated with LVC, there was 1 serious complication, a paraparesis caused by the leakage of cement into the spinal canal, which was partially recovered after decompression and rehabilitation treatment and 2 superificial infections with S. epidermidis which were cured by means of antibiotics. In 32 vertebrae (32) cement leakage extra ossal, either into vein plexus or intradiscal during surgery were noticed. When HVC was applied, intradiscal leakage occurred in one case only (8%). By means od Wilcoxon paired test a significant difference was found between the preoperative VAS, and the values immediately after surgery and 3 months later (Z = 7.52, p < 0.00001) when LVC was applied., and with HVC it was ( Z = 3.04, p < 0.00001), which indicates that the fast achieved pain reduction remained stable during the 3 month follow-up. The vertebroplasty is a safe and efficient surgical method in treatment of compressive vertebrae fractures which do not react to the conventional method of treatment. This method, when HVC is applied, shows significantly less complications related to cement leakage.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20977104

Source DB:  PubMed          Journal:  Coll Antropol        ISSN: 0350-6134


  11 in total

1.  Cement-augmented screws in a cervical two-level corpectomy with anterior titanium mesh cage reconstruction: a biomechanical study.

Authors:  Sebastian Hartmann; Claudius Thomé; Anja Tschugg; Johannes Paesold; Pujan Kavakebi; Werner Schmölz
Journal:  Eur Spine J       Date:  2017-01-21       Impact factor: 3.134

2.  The Rates of Cement Leakage Following Vertebroplasty in Osteoporotic versus Metastatic Disease.

Authors:  Ahmed Saad; Rajesh Botchu; Steven James
Journal:  Indian J Radiol Imaging       Date:  2022-04-19

3.  Cement volume is the most important modifiable predictor for pain relief in BKP: results from SWISSspine, a nationwide registry.

Authors:  Christoph Röder; Bronek Boszczyk; Gosia Perler; Emin Aghayev; Fabrice Külling; Gianluca Maestretti
Journal:  Eur Spine J       Date:  2013-06-18       Impact factor: 3.134

4.  Unipedicular versus bipedicular percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a prospective randomized study.

Authors:  Liang Zhang; Zhongjun Liu; Jingcheng Wang; Xinmin Feng; Jiandong Yang; Yuping Tao; Shengfei Zhang
Journal:  BMC Musculoskelet Disord       Date:  2015-06-14       Impact factor: 2.362

Review 5.  Comparison of high- and low-viscosity cement in the treatment of vertebral compression fractures: A systematic review and meta-analysis.

Authors:  Zhao-Fei Zhang; He Huang; Shuai Chen; Dong-Hua Liu; Yong-Hui Feng; Chun-Liang Xie; Feng Jiao
Journal:  Medicine (Baltimore)       Date:  2018-03       Impact factor: 1.889

6.  Quality of Life in Patients Following Vertebroplasty.

Authors:  Sasa Rapan; Jasna Batrnek; Vjeran Rapan; Egon Biuk; Domagoj Rapan
Journal:  Open Access Maced J Med Sci       Date:  2017-02-04

7.  Clinical comparison between a percutaneous hydraulic pressure delivery system and balloon tamp system using high-viscosity cement for the treatment of osteoporotic vertebral compression fractures.

Authors:  Jie Qin; Jianjun Li; Ying Liu; Bo Zhao; Hui Dong; Bo Dong; Rui Zhang; Ning Ning; Xin Zhang; Feng Cui; Haopeng Li; Xijing He; Dong Wang
Journal:  Clinics (Sao Paulo)       Date:  2019-05-30       Impact factor: 2.365

8.  Pulmonary Artery Cement Embolism after a Vertebroplasty.

Authors:  Anas Nooh; Fahad H Abduljabbar; Ahmed H Abduljabbar; Peter Jarzem
Journal:  Case Rep Orthop       Date:  2015-06-28

9.  Does Balloon Kyphoplasty Deliver More Cement Safely into Osteoporotic Vertebrae with Compression Fractures Compared with Vertebroplasty? A Study in Vertebral Analogues.

Authors:  Fahad H Abduljabbar; Abdulaziz Al-Jurayyan; Saad Alqahtani; Zeeshan M Sardar; Rajeet Singh Saluja; Jean Ouellet; Michael Weber; Thomas Steffen; Lorne Beckman; Peter Jarzem
Journal:  Global Spine J       Date:  2015-02-26

10.  VERTEBROPLASTY IN THE TREATMENT OF VERTEBRAL FRACTURES CAUSED BY PLASMACYTOMA.

Authors:  Vjekoslav Kolarević; Ivan Vidaković; Marko Šutalo; Vjeran Rapan; Domagoj Rapan; Saša Rapan
Journal:  Acta Clin Croat       Date:  2019-09       Impact factor: 0.780

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.