Literature DB >> 20976375

Noninvasive assessment of patients undergoing percutaneous intervention in myocardial infarction.

Rica Dodo Delmar Buchler1, Expedito E Ribeiro, Antonio de Padua Mansur, Paola Smanio, Romeu Sergio Meneghelo, William Azem Chalela, Carlos Alberto Buchpiguel, Jorge Roberto Buchler, Eric R Bates, Eulogio E Martinez.   

Abstract

BACKGROUND: Restenosis after primary percutaneous coronary intervention (PPCI) remains an important clinical problem, even with stent implantation. The ability of noninvasive testing to diagnose restenosis has had only inconsistent demonstration.
OBJECTIVE: Our objective was to evaluate the ability of exercise treadmill testing (ETT) and myocardial perfusion imaging (MPI) to diagnose restenosis in patients treated by PPCI within 12 hours of ST-elevation myocardial infarction (STEMI).
METHODS: From August 2003 to January 2006, 64 patients (mean age of 56.2±10.2 years, 53 males) were enrolled after PPCI. Only patients with left ventricular ejection fraction (LVEF) > 40%, as assessed by resting transthoracic echocardiography (TTE), were included. ETT with 12-lead ECG monitoring and right precordial leads, as also MPI were performed at 6 weeks, 6 months, and one year after intervention. Coronary angiography was performed at six months.
RESULTS: Single-vessel disease was observed in 46.9% of the patients. The left anterior descending coronary artery was treated in 48.4% of the patients. Angiographic restenosis occurred in 28.8%. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of ETT in detecting restenosis were not significant. Right precordial leads did not add information. MPI sensitivity, specificity, PPV, NPV, and accuracy correlated with restenosis only in the 6-month follow-up, both when considering summed difference score >2 (p=0.006) and >4 (p=0.014).
CONCLUSION: ETT did not discriminate restenosis in this population. MPI performed at 6 months correlated with restenosis and proved useful during follow-up.

Entities:  

Mesh:

Year:  2010        PMID: 20976375     DOI: 10.1590/s0066-782x2010005000139

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  1 in total

1.  Adenosine triphosphate stress 99mTc-methoxyisobutylisonitrile gated myocardial perfusion imaging efficacy in diagnosing stent restenosis following coronary stent implantation.

Authors:  Pengfei Zhang; Song Chen; Yang Li; Qiuhong Du; Lijuan Wang; Yingxian Sun; Yaming Li
Journal:  Exp Ther Med       Date:  2016-11-04       Impact factor: 2.447

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.