Literature DB >> 20974526

Adoption of new technology in sports medicine: case studies of the Gore-Tex prosthetic ligament and of thermal capsulorrhaphy.

Sohrab S Virk1, Mininder S Kocher.   

Abstract

Evaluation of new technology in sports medicine is supposed to promote improvements in the care of patients. It is also supposed to prohibit technology that can harm patients. This evaluation process is not perfect and at times can promote technology that not only does not help patients but may harm them. Two examples of new sports medicine technology that were widely adopted but eventually abandoned are thermal capsulorrhaphy for treatment of shoulder instability and the Gore-Tex prosthetic ligament (W. L. Gore & Associates, Flagstaff, AZ) for patients with anterior cruciate ligament deficiency. On analysis of the quick adoption of these 2 failed procedures, certain recommendations are apparent for improvement of the evaluation process. There must be a sound rationale behind any new technology, basic science research into the theory of the medical technology, and demonstrated improvements in animal models and clinical studies that are prospective cohort studies or randomized controlled trials, and finally, there must be careful follow-up and postmarket surveillance.
Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20974526     DOI: 10.1016/j.arthro.2010.06.001

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  4 in total

1.  Editor's Spotlight/Take 5: No Benefit After THA Performed With Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.

Authors:  Seth S Leopold
Journal:  Clin Orthop Relat Res       Date:  2016-06-09       Impact factor: 4.176

2.  No free lunch in orthopedics.

Authors:  Benjamin A Goldberg; Marius M Scarlat
Journal:  Int Orthop       Date:  2017-10       Impact factor: 3.075

Review 3.  Heat-Related Complications from Radiofrequency and Electrocautery Devices Used in Arthroscopic Surgery: A Systematic Review.

Authors:  Carola F van Eck; Tim A C van Meel; Michel P J van den Bekerom; Jacco A C Zijl; Bauke Kooistra
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-02-23

Review 4.  Comparison of biomechanical studies of disc repair devices based on a systematic review.

Authors:  Sohrab Virk; Tony Chen; Kathleen N Meyers; Virginie Lafage; Frank Schwab; Suzanne A Maher
Journal:  Spine J       Date:  2020-02-22       Impact factor: 4.297

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.