Literature DB >> 20974498

Intra-aortic balloon pumping recruits graft flow reserve by lowering coronary resistances.

Antonino S Rubino1, Francesco Onorati, Cristian Scalas, Giuseppe F Serraino, Roberto Marsico, Sandro Gelsomino, Roberto Lorusso, Attilio Renzulli.   

Abstract

BACKGROUND: The intra-aortic balloon pump (IABP) is used worldwide as an anti-ischemic strategy and to reduce myocardial workload. However, whether IABP augments coronary flow after coronary bypass via a passive increase in diastolic pressure or an active response of the coronary bed remains uncertain.
METHODS: We analyzed transit-time flow measurements and the contemporary changes in coronary resistances obtained during 1:1 IABP and during its cessation in 144 consecutive patients receiving prophylactic IABP before isolated coronary artery bypass grafting (n=340 graft segments).
RESULTS: Normally functioning grafts showed lower coronary resistances, greater percentage decrease in resistance, and greater increases in average maximum diastolic and mean flow during 1:1 IABP compared with IABP cessation (P<.001). Arterial and sequential saphenous vein grafts showed better flowmetry and greater reductions in coronary resistances compared with single venous grafts. Accordingly, graft flow reserve (defined as mean flow during 1:1 IABP/mean flow with IABP off) was recruited (graft flow reserve >1) during 1:1 IABP in all normally functioning grafts, with higher values in single arterial or sequential saphenous vein grafts than in single venous grafts (both P<.001). Coronary resistances were higher in 7 failed grafts versus normal-functioning grafts at baseline; these did not decrease during 1:1 IABP and showed worse transit-time flow results.
CONCLUSIONS: IABP recruits graft flow reserve by lowering coronary resistance in functioning grafts. Arterial and sequential venous grafts showed greater reduction in coronary resistance compared with single saphenous grafts.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20974498     DOI: 10.1016/j.ijcard.2010.09.058

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  3 in total

1.  Preoperative intra-aortic balloon pump improves the clinical outcomes of off-pump coronary artery bypass grafting in left ventricular dysfunction patients.

Authors:  Feng Yang; Jinhong Wang; Dengbang Hou; Jialin Xing; Feng Liu; Zhi Chen Xing; Chunjing Jiang; Xing Hao; Zhongtao Du; Xiaofang Yang; Yanyan Zhao; Na Miao; Yu Jiang; Ran Dong; Chengxiong Gu; Lizhong Sun; Hong Wang; Xiaotong Hou
Journal:  Sci Rep       Date:  2016-06-09       Impact factor: 4.379

2.  Preserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation.

Authors:  Hiroyuki Nakajima; Atsushi Iguchi; Mimiko Tabata; Masaru Kambe; Masahiro Ikeda; Kazuhiko Uwabe; Toshihisa Asakura; Hiroshi Niinami
Journal:  J Cardiothorac Surg       Date:  2016-11-28       Impact factor: 1.637

3.  Intraoperative Assessment of Coronary Resistances: A New Quality Marker and Potential Tool to Predict Early Graft Failure after Coronary Artery Bypass Grafting?

Authors:  Antonino Salvatore Rubino; Fabrizio Ceresa; Liborio Mammana; Giuseppe Vite; Gianluca Cullurà; Augusto Palermo; Aurora Leonardi; Bruna Filomena De Donno; Francesco Patanè
Journal:  J Cardiovasc Dev Dis       Date:  2021-11-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.