Literature DB >> 20971554

Ionic liquid ultrasound assisted dispersive liquid-liquid microextraction method for preconcentration of trace amounts of rhodium prior to flame atomic absorption spectrometry determination.

Elaheh Molaakbari1, Ali Mostafavi, Daryoush Afzali.   

Abstract

In this article, we consider ionic liquid based ultrasound-assisted dispersive liquid-liquid microextraction of trace amounts of rhodium from aqueous samples and show that this is a fast and reliable sample pre-treatment for the determination of rhodium ions by flame atomic absorption spectrometry. The Rh(III) was transferred into its complex with 2-(5-bromo-2-pyridylazo)-5-diethylamino phenol as a chelating agent, and an ultrasonic bath with the ionic liquid, 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide at room temperature was used to extract the analyte. The centrifuged rhodium complex was then enriched in the form of ionic liquid droplets and prior to its analysis by flame atomic absorption spectrometry, 300 μL ethanol was added to the ionic liquid-rich phase. Finally, the influence of various parameters on the recovery of Rh(III) was optimized. Under optimum conditions, the calibration graph was linear in the range of 4.0-500.0 ng mL(-1), the detection limit was 0.37 ng mL(-1) (3S(b)/m, n = 7) and the relative standard deviation was ±1.63% (n = 7, C = 200 ng mL(-1)). The results show that ionic liquid based ultrasound assisted dispersive liquid-liquid microextraction, combined with flame atomic absorption spectrometry, is a rapid, simple, sensitive and efficient analytical method for the separation and determination of trace amounts of Rh(III) ions with minimum organic solvent consumption.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20971554     DOI: 10.1016/j.jhazmat.2010.09.067

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  3 in total

1.  Determination of trace amounts of zirconium in real samples after microwave digestion and ternary complex dispersive liquid-liquid microextraction.

Authors:  Daryoush Afzali; Fariba Fathirad; Sima Ghaseminezhad; Zahra Afzali
Journal:  Environ Monit Assess       Date:  2014-02-01       Impact factor: 2.513

Review 2.  Determination of Heavy Metal Ions and Organic Pollutants in Water Samples Using Ionic Liquids and Ionic Liquid-Modified Sorbents.

Authors:  Minglei Tian; Luwei Fang; Xuemin Yan; Wei Xiao; Kyung Ho Row
Journal:  J Anal Methods Chem       Date:  2019-10-31       Impact factor: 2.193

Review 3.  Application of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction techniques in analytical toxicology.

Authors:  Vahid Sharifi; Ali Abbasi; Anahita Nosrati
Journal:  J Food Drug Anal       Date:  2016-01-07       Impact factor: 6.157

  3 in total