Literature DB >> 20971245

Efficacy and safety of very low-dose self-management of oral anticoagulation in patients with mechanical heart valve replacement.

Heinrich Koertke1, Armin Zittermann, Otto Wagner, Juergen Ennker, Werner Saggau, Falk-Udo Sack, Jochen Cremer, Christof Huth, Maurizio Braccio, Francesco Musumeci, Reiner Koerfer.   

Abstract

BACKGROUND: Self-management improves oral anticoagulation control. Here we provide data of a preplanned interim analysis of very low-dose early self-controlled anticoagulation.
METHODS: In a prospective, randomized, multicenter trial, 1,137 patients performed low-dose international normalized ratio (INR) self-management with a target INR range of 1.8. to 2.8 for aortic valve replacement recipients and 2.5 to 3.5 for mitral or double valve replacement recipients for the first six postoperative months. Thereafter, 379 patients continued to achieve the aforementioned INR target range (LOW group), whereas the INR target value was set at 2.0 (range, 1.6 to 2.1) for the remaining patients with aortic valve replacement and 2.3 (range, 2.0 to 2.5) for the remaining patients with mitral valve or double valve replacement. One half of this latter group had to check their INR values once a week (VL1 group) the other half twice a week (VL2 group). Patients were followed up for 24 months.
RESULTS: Beyond study month six, the incidence of thromboembolic events that required hospital admission was 0.58%, 0.0%, and 0.58% in the LOW, VL1, and VL2 groups, respectively (p = 0.368). The incidence of bleeding events per patient-year was 1.16%, 1.07%, and 0.58% in the LOW, VL1, and VL2 groups, respectively (p = 0.665). Mortality rate did not differ among study groups.
CONCLUSIONS: Data demonstrate the efficacy and safety of very low-dose INR self-management.
Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20971245     DOI: 10.1016/j.athoracsur.2010.06.069

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  9 in total

1.  Long-term self-management of anticoagulation therapy after mechanical heart valve replacement in outside trial conditions.

Authors:  Helmut Mair; Jörg Sachweh; Ralf Sodian; Paolo Brenner; Michael Schmoeckel; Christoph Schmitz; Bruno Reichart; Sabine Daebritz
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-12-07

2.  American Society of Hematology 2018 guidelines for management of venous thromboembolism: optimal management of anticoagulation therapy.

Authors:  Daniel M Witt; Robby Nieuwlaat; Nathan P Clark; Jack Ansell; Anne Holbrook; Jane Skov; Nadine Shehab; Juliet Mock; Tarra Myers; Francesco Dentali; Mark A Crowther; Arnav Agarwal; Meha Bhatt; Rasha Khatib; John J Riva; Yuan Zhang; Gordon Guyatt
Journal:  Blood Adv       Date:  2018-11-27

Review 3.  Self-monitoring and self-management of oral anticoagulation.

Authors:  Carl J Heneghan; Josep M Garcia-Alamino; Elizabeth A Spencer; Alison M Ward; Rafael Perera; Clare Bankhead; Pablo Alonso-Coello; David Fitzmaurice; Kamal R Mahtani; Igho J Onakpoya
Journal:  Cochrane Database Syst Rev       Date:  2016-07-05

4.  Late clinical outcomes after mechanical aortic valve replacement for aortic stenosis: old versus new prostheses.

Authors:  Heemoon Lee; Kiick Sung; Wook Sung Kim; Dong Seop Jeong; Joong Hyun Ahn; Keumhee Chough Carriere; Pyo Won Park
Journal:  J Thorac Dis       Date:  2018-06       Impact factor: 2.895

5.  Optimal INR level for warfarin therapy after mechanical mitral valve replacement.

Authors:  Itthidet Kamthornthanakarn; Rungroj Krittayaphong
Journal:  BMC Cardiovasc Disord       Date:  2019-04-25       Impact factor: 2.298

6.  Self-management of patients with heart valve replacement and its clinical outcomes: a systematic review.

Authors:  Shirdel Zandi; Behzad Imani; Gholamreza Safarpor; Salman Khazaei
Journal:  Kardiochir Torakochirurgia Pol       Date:  2021-05-15

7.  Outcomes related to anticoagulation management for mechanical valve replacements.

Authors:  Lauren V Huckaby; Laura M Seese; Thomas G Gleason; Ibrahim Sultan; Yisi Wang; Floyd Thoma; Arman Kilic
Journal:  J Thorac Dis       Date:  2021-05       Impact factor: 2.895

8.  Acute thrombosis of mechanical bi-leaflet aortic valve prosthesis.

Authors:  Theodor Tirilomis
Journal:  J Cardiovasc Dis Res       Date:  2012-07

9.  The effects of a low international normalized ratio on thromboembolic and bleeding complications in patients with mechanical mitral valve replacement.

Authors:  Ugur Bal; Alp Aydinalp; Kerem Yilmaz; Emre Ozcalik; Senem Hasirci; Ilyas Atar; Bahadir Gultekin; Atilla Sezgin; Haldun Muderrisoglu
Journal:  J Cardiothorac Surg       Date:  2014-05-07       Impact factor: 1.637